19
N.Install Electrical System
Connect the power source on the data plate of Motor.
Note: 1. For the safety of operators, the power wiring must contact the floor well.
2. Pay attention to the direction of rotations when using 380V, three phase
motors.
Single phase motor
(See Fig. 31)
.
1.
Connecting the two power supply lines (fire wire
L
and zero wire
N
) to terminals of
AC contactor marked
L1, L2
respectively.
2.
Connecting the two motor wires to terminals of AC contactor marked
T1, T2
.
3.
Connecting
A2
of AC contactor to
L2
.
4.
Connect the two push button wires to the terminals of AC contactor marked A1,L1.
Fig. 31
Push button
AC contactor
Single phase