B. Equipment storage and installation requirements.
The equipment should be stored or installed in a shady, normal temperature,
ventilated and dry place.
C. The equipment should be unload and transfer by forklift.
D. SPECIFICATIONS OF CONCRETE
(See Fig. 5)
Specifications of concrete must be adhered to the specification as following.
Failure to do so may result in lift and/or vehicle falling.
1. Concrete must be thickness 4’’ minimum and without reinforcing steel bars
,
and must be
dried completely before the installation.
2. Concrete must be in good condition and must be of test strength 3,000 psi (210kg/cm²)
minimum.
3. Floors must be level and no cracks.
E. AIR SUPPLY
Air pressure requirement: 0.5Mpa~0.8Mpa, Air line size
¢
8
×¢
6 and
¢
6
×¢
4.
F. POWER SUPPLY
The electrical source must be 2.0HP minimum. The source cable size must be 2.5mm² and in
good condition of contacting with floor.
Fig. 5
Fig. 4
≥4’’