35
V. TEST RUN
1. Adjust synchronous cable
(See Fig. 45)
Use Spanner to hold the cable fitting, meanwhile
use ratchet spanner to tighten the cable nut.
Make sure two cables are with the same tension
so that two carriages can work synchronously.
If the carriage does not Synchronize when lifting , please tighten the cable nut.
2. Adjust safety cable
Lifting the carriages and lock at the same height, strain the safety cable and then
release a little, and then tighten the cable nuts. Make sure the safety device can
always be worked properly.
3. Exhaust air
This hydraulic system is designed to bleeding air by loosing
the bleeding plug. Lifting the carriages to about 1 meter
height, and loose the bleeding plug, the air would be
bled automatically, then tighten the plug after bleeding,
the lift would work stably and smoothly,
otherwise repeat bleeding
(See Fig. 46)
.
Cable nut
Fig. 45
Bleeding plug
Fig. 46
Summary of Contents for OH-12
Page 1: ...Two Post Lift Model OH 12 Original...
Page 4: ...2 Arm Swings View Fig 2 3829mm 2787mm 109 3 4 150 3 4...
Page 17: ...15 K Lift the carriages up by hand and make them be locked at the same level See Fig 26 Fig 26...
Page 28: ...26 IV EXPLODED VIEW Model OH 12 Fig 40...
Page 34: ...32 4 3 Manual Power unit 071102 220V 60HZ Single Phase Fig 43...