S-4000 TKF, LS Omron
1-25
Released 12/2009
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
D - MACHINE CONTROLS
5. TESTS
WARNING! ONLY PROFESSIONAL SERVICE TECHNICIANS SHOULD PERFORM THESE TESTS!
The main screen appears on the display. Press
, appears on the display. To
enter the tests menu, press
key. The follwing screen appears on the display .
To scroll this menu down, press
key, to scroll this menu up, press
key.
NOTE:
Before performing the tests, press and release the Emergency Stop button to disconnect the motor.
INPUTS TESTS
1.
Low air pressure
-
Low air pressure off
appears on the display. If the air pressure is lower than 0,5 MPa,
the message
Low air pressure on
appears on the display. The switch BQ 2 is tested
by this parameter.
2.
Home senzor
-
the end position sensor.
Home sensor off
appears on the display. Activate the sensor
using a metal tool.
Home sensor on
appears on the display. Switch BQ1 is tested by
this
parameter.
3.
Voltage rly
-
Voltage rly off
appears on the display. If the power supply drops below 185 V,
the
Voltage rly on
appears on the display. Only in case the relay VC 1 in installed.
4.
Pedal 1 step
-
Pedal 1 step off
appears on the display. When the foot pedal is pressed to its first
position, the
Pedal 1 step on
appears on the display. Switch SB4 is tested by this
parameter.
5.
Pedal 2 step
-
Pedal 2 step off
appears on the display. When the foot pedal is pressed to its
second position, the
Pedal 2 step on
appears on the display. Switch SB5 is tested
by this parameter.
6.
Em Stop
-
after the Emergency Stop button is pressed, the
Em Stop off
appears on the display.
After the Emergency Stop button is released, the
Em Stop on
appears on the display.
Switch SA1 is tested by this parameter.
7.
Clamp Button
-
Clamps button off
appears on the display. When the clamp Up/Down button is
pressed the
Clamp button on
appears on the display. Switch SB3 is tested by this
parameter.
8.
Motor ready
-
Motor ready off
appears on the display (motor is off).
Motor ready on
appears on the display (motor is on) servodrive U2 is tested B4 this
parameter.
www.promelectroavtomat.ru
Summary of Contents for S 4000 LS
Page 4: ...www promelectroavtomat ru...
Page 68: ...www promelectroavtomat ru...