B - MACHINE ASSEMBLY
4 . P OW E R A N D A I R C O N N E C T I O N
1.
The machine is equipped with a quick coupler
➍
required with connector for inner
∅
of the tube 10.
The connector for inner
∅
of the tube 8 is not supplied with
the machine, a customer has to order it. The manufacturer
recommends to use connector
➏
for customers who requires
to connect the tube with connector NPT.
If a customer needs to use a shut off valve
➊
, which allows
fast releasing of the air from the circuit, he must order it.
A variety of connectors
➋
can be used separately or in
combination to adapt to the available input supply hose. It
depends on type of the tube which is used by a customer.
These connectors are not included in the accessories. A
tubing clamp
➌
is provided.
N O T E :
Parts
➊
,
➋
,
➎
,
➏
are included in Extra Parts - see
3-47.
2.
After air connection check the set air pressure on the dial of the regulator. It should be in range
0.5 - 0.6 MPa. The green pointer
➐
indicates the lowest working air pressure 0.5 MPa, which is set
from the manufacturer on the regulator
➑
. If the air pressure is lower than 0.5 MPa after connecting
the machine to the power supply „Low Pressure“ message appears on the control panel display. To
adjust the working pressure, loosen the regulator cap lock
➓
and turn the regulator cap clockwise to
increase the pressure. Push the regulator cap
➓
down. The LED
is for setting the minimal operation
air pressure.
3.
Power supply must be 208 to 230 volts 1 phase, 50 or 60 hertz. Receptacle plug must meet
requirements of IEC standard 364-4-41, its circuit breaker must be minimal 10A with characteristic
C according to the EN 60947-2 (or 16A with characteristic B). No other devices must not be connected
to the circuit breaker of the socker. The hand wheel
must turn counter clockwise.
The machine is equipped with a filters which contain capacitors which generate an high frequency
leakage current. In order to prevent nuisance tripping, residual current protection device must be
protected against these high frequency currents: this is the case for industrial residual current
device (example „S“ type).