ATX
6
26
The car will be out of control if the battery runs out, please immediately stop running when the alarm
starting to ring.
4.20 Gyro Sensitivity
This function is available to set gyro sensitivity and VR mixing ON or
OFF.
When MIX set OFF, gyro is disabled while when MIX set ON, you can
adjust gyro sensitivity STD or VR. STD is adjusted on screen and VR
is default CH3.
In normal mode (STD), range of sensitivity is 0%-100%.
(1) Enter the menu, use (-) and (+) to select options for gyro
sensitivity.
(2) Press the key button “Enter” to enter sub
-menu gyro sensitivity.
(3) Press “Enter” again, the initial value will start flashing, then use D(
-
) and (+) to change the value.
(4) Press the button key “Enter”, the value stops flashing, the setting is finished now.
(5) "Mode" and "Rate" can also be set by the same step.
(6) Press button key “Exit” to be back to initial screen
.
4.21 Fail Safe
This function is set by servo, throttle, CH3, CH4, CH5 and CH6.
RANGE:
ST: -100 ~ +100
TH: -100 ~ +100
CH3: -100 ~ +100
CH4: -100 ~ +100
CH5: -100 ~ +100
CH6: -100 ~ +100
Initial value: 0
(1) Enter the menu, use “(
-
)” and “(+)” to select options to set.
(2) Press the button key “Enter” to enter menu.
(3) Use “(
-
)” and “(+)” to select SERVO, then press “Enter”. Now the
initial value of SERVO will start flashing, use handle to change the
value.
(4) Press the button key “Enter”, the value stops flashing, now the
value of SERVO is set.
(5) THROTTLE is to set by the trigger.
CH3 is to set by VR controller.
CH4 is to set by the button switch.