TW 5250 • TW 3500 • TW 1750 Operation
Elgar TrueWave 3-9
PHASE A OUT (default)
This specifies that the BNC will provide a pulse on each 0
crossing of Phase A
TRIG IN
This mode provides for the external synchronization of specific
events (disturbance).
CONTROL
The BNC connector labeled “EXT” is configured here
CONT OFF (default)
The amplifiers are not externally controlled when this setting is
specified.
CONT DIRECT
This setting allows a control voltage of 5Vrms (+/- 7.07 Vpeak)
to directly control the amplifiers.
CONT GAIN
This setting allows a control voltage of 5Vrms (+/- 7.07 Vpeak)
to scale the output waveform. (0 - +/- Full Scale Output)
SENSE
The amplifier sense point is either external (remote,distant) or internal (local) and
is adjustable here
LOCAL
The amplifiers are controlled independent of the external sense lines.
DISTANT (default)
The amplifiers are controlled via the external sense lines feedback.
CHASSIS
The chassis quantity is set here (for Master/Slave TW application)
CHAS QTY
Set the number of chassis (factory default 1)
IEC SETTING
Sets the reference impedance of the output to support IEC hardware
IEC ON
Sets output to support IEC reference impedance mode of operation
IEC OFF
Sets output to normal impedance