![Ametek TW1750 Operation Manual Download Page 15](http://html.mh-extra.com/html/ametek/tw1750/tw1750_operation-manual_3043986015.webp)
TW 5250 • TW 3500 • TW 1750 General Description
Elgar TrueWave 1-5
Output Current Accuracy
0.3% of full scale + 0.5% of reading maximum
Output Current Resolution
0.01 Amps RMS maximum
Output Power Range
0 to 1900 W per phase minimum
Output Power Accuracy
2.5% of full scale maximum
Output Power Resolution
10 W maximum
Crest Factor Accuracy
1% of full scale maximum for output > 200VA
Power Factor Accuracy
4% of full scale maximum for output > 200VA
Frequency Accuracy
0.25% of reading
Output Phase Accuracy
0.5%
Output Phase Resolution
0.3%
1.5 GPIB AND RS-232 READBACK
Output Voltage Accuracy
0.3% of full scale + 0.2% of reading maximum
Output Voltage Resolution
0.1 VRMS maximum
Output Current Accuracy
0.3% of full scale + 0.5% of reading maximum
Output Current Resolution
0.01 Amps RMS maximum
Output Power Range
0 to 1900 W per phase minimum
Output Power Accuracy
2.5% of full scale maximum
Output Power Resolution
10 W maximum
Crest Factor Accuracy
1% maximum for output > 200VA
Power Factor Accuracy
4% maximum for output > 200VA
Output Phase Accuracy
0.5%
Output Phase Resolution
0.3%