TR-2100 User Manual
15
•
The TR can’t read a sensor
•
There is a major difference between two sensors
Test Button
The 'Test' button on the front panel may be used at any time to check that the TR-2100 is
operating correctly. When the button is pressed, a series of internal tests are performed and a
manual trigger is performed. If a local printer is connected, the system configuration and
record will be printed. Alternatively, Display Station can be connected to read and display
the data. If the TR-2100 detects a fault during these tests, it will switch on the 'Attention'
indicator. The cause of the problem can be found by reading the event log with Display
Station.
Disarm triggering
The 'Test' button may also be used to disarm all triggering within the TR-2100. This may be
required if maintenance is being performed on the monitored lines or transformers when
extraneous triggering could occur. By pushing the 'Test' button for 5 seconds, the 'On Line'
LED will go out, indicating that all triggering is disarmed. There is also a tone that changes
from a low to high pitch when the triggers disarm.
To rearm the recorder, press the 'Test' button again briefly. Since the recorder is not yet
armed, no test record will be generated. The Disarm function is also available in the
Recorder Configuration window of Display Station. Messages are placed in the alarm log
that indicates the time/date the system was disarmed and re-armed.
Status Outputs
The four solid-state status relay outputs are situated on the left of the lower input board.
These are specified as normally open contacts. The power relay is held on by the main
supply. The others are software controlled and switched on to indicate the designated
function.
The four defined functions are as follows:
Power
Duplicates the function of the front panel LED.
On Line
Duplicates the function of the front panel LED.
Triggered
The relay is activated while the TR-2100 is triggered with a minimum on-time of 500 ms.
This relay has a slightly different function if the recorder cross-triggering is enabled (see
Section 2).
Attention
Summary of Contents for TR-2100
Page 2: ......
Page 6: ...iv ...
Page 10: ...TR 2100 User Manual 4 ...
Page 16: ...TR 2100 User Manual 10 ...
Page 24: ...TR 2100 User Manual 18 ...
Page 34: ...TR 2100 User Manual 28 ...
Page 38: ...TR 2100 User Manual 32 ...
Page 54: ...TR 2100 User Manual 48 Figure 12 Analogue Input Board Jumpers ...
Page 78: ...TR 2100 User Manual 72 ...
Page 94: ...TR 2100 User Manual 88 ...
Page 98: ...TR 2100 User Manual 92 ...
Page 99: ...TR 2100 User Manual 93 Appendix V System Drawings ...
Page 100: ...TR 2100 User Manual 94 ...
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......