32
13.2.1 Special ANSI C62.45 couplings
Selected coupling for single phase systems (one line and neutral with ground)
Connection of generator
Test type
Ground
Neutral
Line
Basic 1
Lo
HN
HH
Basic 2
Lo
Supplemental 1
Lo
HN
Supplemental 2
Lo
HH
Diagnostic 1
HN
Lo
Diagnostic 2
Lo
HH
Lo:
Connection to Surge generator low
H
G
:
Connection to surge generator high
H
N
:
Connection to surge generator high by coupling to capacitor C
N
H
H
:
Connection to surge generator high by coupling to capacitor C
H
Selected coupling for single phase systems
(two lines and neutral with ground)
Connection of generator
Test type
Ground
Neutral
Line 1
Line 2
Basic 1
Lo
HN
H1
H2
Basic 2
Lo
H1
Basic 3
Lo
H2
Supplemental 1
Lo
HN
Supplemental 2
Lo
H1
Supplemental 3
Lo
H2
Diagnostic 1
Lo
H1
H2
Diagnostic 2
Lo
H1
H2
Selected coupling for single phase systems (3-phase lines and neutral with ground)
Connection of generator
Test type
Ground
Neutral
Line 1
Line 2
Line 3
Basic 1
Lo
HN
H1
H2
H3
Basic 2
Lo
H2
Basic 3
Lo
H3
Basic 4
H1
H1
Lo
Supplemental 1
Lo
HN
Supplemental 2
Lo
H1
Supplemental 3
Lo
H2
Supplemental 4
Lo
H3
Diagnostic 1
Lo
H1
H2
H3
Diagnostic 2
Lo
H1
H2
H3
Lo:
Connection to Surge generator low
H
G
:
Connection to surge generator high
H
N
:
Connection to surge generator high by coupling to capacitor C
N
H
1
:
Connection to surge generator high by coupling to capacitor C
1
H
2
:
Connection to surge generator high by coupling to capacitor C
2
H
3
:
Connection to surge generator high by coupling to capacitor C
3
For more information see IEEE/ANSI Standard C62.45