background image

Contact Us

UK - Dronfield

Land Instruments International

Tel:       +44 (0) 1246 417691

USA - Pittsburgh

AMETEK Land, Inc.

Tel:      +1 412 826 4444

China

AMETEK Land

 China Service 

Tel: 

+86 21 5868 5111 ext 122

India

AMETEK Land

 India Service

Tel:     +91 - 80 67823240 

Email:   [email protected]
Web:     www.ametek-land.com

For further details on all AMETEK Land offices, distributors and representatives, please visit our website.

Return of Damaged Goods

IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the 

supplier immediately. Damage caused in transit is the responsibility of the carrier not the supplier.
DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim. Save 

the packing with the damaged article for inspection by the carrier.

Return of Goods for Repair

If you need to return goods for repair please contact our Customer Service Department. They will be able 

to advise you on the correct returns procedure.

Any item returned to Land Instruments International should be adequately packaged to prevent damage 

during transit.
You must include a written report of the problem together with your own name and contact information, 

address, telephone number, email address etc.

Design and Manufacturing Standards

The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for 

the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact 

temperature measuring instrumentation.
Registered ISO 9001 Management System approvals apply in the USA

UK Calibration Laboratory: UKAS 0034
USA Calibration Laboratory: ANAB Accredited ISO/IEC 17025
National Accreditation Board for Testing and Calibration Laboratories 

approvals apply in India.

Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity 

to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause 

interference and possible failure where the radiated emissions exceed the EMC directive.

 

The protection provided by this product may be invalidated if alterations or additions are made to the 

structural, electrical, mechanical or pneumatic parts of this system. Such changes may also invalidate the 

standard terms of warranty.

Copyright

This manual is provided as an aid to owners of Land Instruments International’s products and contains 

information proprietary to Land Instruments International. This manual may not, in whole or part, be 

copied, or reproduced without the expressed written consent of Land Instruments International Ltd.

Copyright © 2018 Land Instruments International.

MARCOM0311, Issue 9, 12 April 2018

Summary of Contents for Land FTI-Eb

Page 1: ...Installation Guide Issue 4 30 April 2011 Publication N 805502 Language English FTI Eb Thermal Imaging Solutions for Furnaces and Boilers Land Instruments International 2018...

Page 2: ...e user documentation supplied before installing and operating the equipment The safety of any system incorporating this equipment is the responsibility of the assembler Protective Clothing Face and Ey...

Page 3: ...ign and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environment...

Page 4: ...Installation Guide FTI Eb Fixed Thermal Imaging System...

Page 5: ...Eb Rugged Enclosure and Mounting Dimensions B4 Fig 3 FTI Eb PSU Mounting Details B5 Fig 4 FTI Eb Camera Installation and Dimension Diagrams B6 Fig 5 FTI Eb System Electrical interconnection Diagrams a...

Page 6: ...Installation Guide FTI Eb Fixed Thermal Imaging System...

Page 7: ...a series of simple installation diagrams covering the installation of the FTI Eb thermal camera and its mountings accessories and services The equipment must be used maintained and serviced by proper...

Page 8: ...uirement 100 to 240V ac 1 0A 50 60Hz EMC EN61326 Safety EN61010 1 Camera Operating Temp Range 5 to 50 C 40 to 120 F 1 Sealing IP65 Weight 4 5kg 10lb EMC EN61326 IP Address 10 1 10 10x Default 10 1 10...

Page 9: ...a NUDAM 6063 Relay Output Module 7 isolated relay outputs Output type form A Contact rating AC 0 5A 125V DC 1A 30V Isolation 1000 M 500V DC Analog Input via NUDAM 6018 Thermocouple Analog Input Module...

Page 10: ...sure that the air flow within the computer is sufficient to adaquately cool the machine make sure that any remaining expansion slot covers are in place Refer to the PC Operating Instructions Replace t...

Page 11: ...in 8 White Pin 5 Black Yellow DATA Pin 9 Green On the port which is connected to the NUDAM input output modules go into Properties and then Port Settings Check the box for RS485 Half Duplex Windows wi...

Page 12: ...clean cloth moistened with either water or a mild neutral detergent The optical tube front window can be cleaned by wiping with a lens tissue For stubborn dirt use a lens cleaner or alcohol on a soft...

Page 13: ...w of water at all times when the probe assembly is mounted even when the furnace is cold or the camera is not present The weight of the unit must be supported beneath the camera housing and NOT by the...

Page 14: ...Section A Page 8 Fixed Thermal Imaging System Installation Guide Water Air Requirements NOTE Apply to water temperature 25 C 77 F...

Page 15: ...Fixed Thermal Imaging System B1 Installation diagrams This section of the Installation Guide contains a series of simple installation diagrams covering the installation of the FTI Eb thermal camera a...

Page 16: ...Section B Page 2 Installation Guide FTI Eb Fixed Thermal Imaging System Fig 1 FTI Eb System Overview...

Page 17: ...Section B Page 3 Installation Guide FTI Eb Fixed Thermal Imaging System Fig 2a Rugged Enclosure and Mounting Dimensions...

Page 18: ...Section B Page 4 Installation Guide FTI Eb Fixed Thermal Imaging System Fig 2b Rugged Enclosure and Mounting Dimensions...

Page 19: ...rmal Imaging System 152 0mm 5 9 230 0mm 9 05 DOOR SWING 12 5mm 0 5 50 1 96 200 0mm 7 9 255 0mm 10 04 242 0 9 5 300 0 11 8 MOUNTING HOLES 4 OFF 10 0mm 0 39 CONDUIT FITTING FOR CABLE TO RUGGED HOUSING C...

Page 20: ...T IP ADDRESS OPEN COVER AND ROT IP ADDRESS 10 1 10 10X WHERE X ROTARY SWITCH POSI FACTORY DELIVERED ADDRESS 10 1 10 102 POSITION 0 IS ONLY CONNECT CABLE TO THIS CONNECTOR ON IMAGER NOTE ALIGN RED DOTS...

Page 21: ...Section B Page 7 Installation Guide FTI Eb Fixed Thermal Imaging System Fig 5 Electrical interconnection Diagrams and Cable Requirements for FTI CP...

Page 22: ...CP CUSTOMER 2 ETHERNET DTP CAT 5 6 or F O SC MULTIMODE LAND 3 CABLE CAMERA TO FTI E CP MODULE 4 LAND 25mm OD FLEXIBLE CONDUIT LAND Pt No 801101 10m LAND Pt No 803970 10m OR 803971 20m 3 WAY MAINS CAB...

Page 23: ...380 0 14 9 MOUNTING HOLES 4 OFF 10 0mm 0 39 CONDUIT FITTING FOR CABLE TO RUGGED HOUSING Optional touch screen interface 1 1 0 0 600 23 6 CASE BOTTOM NOTES 1 MUST BE MOUNTED VERTICAL WITH CABLE ENTRIE...

Page 24: ...OR ON REAR OF RUGGED HOUSING LAND SUPPLIED 25mm OD CONDUIT Pt No 801101 CONNECT THIS END OF CONDUIT TO REAR OF RUGGED HOUSING UNOBSCURED ISOLATOR SWITCH MAINS CABLE VIEW WITH GLAND PLATE REMOVED CAMER...

Page 25: ...UGGED HOUSING LAND SUPPLIED 25mm OD CONDUIT Pt No 801101 CONNECT THIS END OF CONDUIT TO REAR OF RUGGED HOUSING COMPUTER ETHERNET CONNECTION USE ANY SPARE SOCKETS 1 TO 3 OR 5 FOR FIBRE OPTIC MULTIMODE...

Page 26: ...2 DI0 RL1 COM GND A VIN0 13 DI1 RL2 NO VOUT B VIN1 14 DI1 RL2 COM GND B VIN1 15 DI2 RL3 NO VOUT C VIN2 16 DI2 RL3 COM GND C VIN2 17 DI3 RL4 NO VOUT D VIN3 18 DI3 RL4 COM GND D VIN3 19 DI4 RL5 NO VIN4...

Page 27: ...hermometers accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VDT U DTT FLT5 A This 36 month war...

Page 28: ...side the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral pH etc overhea...

Reviews: