MX15
147
FREQUENCY TRANSIENTS
(A(CF) only)
Test 1
Seq. No.
Volt/Frequency
Time
1
115/400
5 minutes
2
115/350
5 sec.
3
115/320
0.2 sec.
4
0/320
0.2 sec.
5
115V/400
10 sec.
Test 2
Seq. No.
Volt/Frequency
Time
1
115/400
5 minutes
2
115/480
0.2 sec.
3
115/440
5 sec.
4
0/440
0.2 sec.
5
115V/400
10 sec.
FREQUENCY TRANSIENTS
(Group 1 only)
Seq. No.
Frequency
Time
1
400
5 minutes
2
480
5 sec.
3
400
10 sec.
4
320
5 sec.
5
400
10 sec.
Table 9-11: Abnormal Frequency Transient
This test will set the voltage at 115V and will remain at this voltage through out the test except
for the A(CF) category. The test will cycle the frequency three times as shown in Table 9-11.
Each repeat will start from sequence 2. Test1 and test2 for the A(CF) category are done in
succession as a single test.
Summary of Contents for California Instruments MX15 Series
Page 1: ...7005 960 Rev N www programmablepower com MX15 Series AC and DC Power Source User Manual...
Page 29: ...MX15 Series 29 Figure 2 5 MX output filter option schematic...
Page 30: ...30 Figure 2 6 MX15 Output Noise 10 KHz 1 MHz...
Page 31: ...MX15 Series 31 Figure 2 7 MX45 Output Noise 10 KHz 1 MHz with Optional Filter...
Page 36: ...36 Figure 3 3 MX Series AC Input Connection Diagram Rear view...
Page 43: ...MX15 Series 43 Figure 3 8 Two MX s in Clock and Lock mode Output Wiring Rear view...
Page 45: ...MX15 Series 45 Figure 3 10 Three MX s in Clock and Lock mode Output Wiring Rear view...
Page 58: ...58 Figure 3 15 Functional Test Setup...
Page 106: ...106 Figure 5 2 MX Series Detailed Block Diagram...
Page 107: ...MX15 Series 107 Figure 5 3 Power Module Detailed Block Diagram...
Page 111: ...MX15 111 Figure 5 5 Amplifier Board Layout...
Page 139: ...MX15 139 Figure 9 4 Voltage Modulation Frequency characteristics...