Page 5
For technical questions, please call 1-888-866-5797.
Item 64017
Sa
F
ety
Opera
ti
O
n
Maintenance
Setup
Specifications
DC Voltage
Ranges: 60mV / 600mV / 6V / 60V / 600V / 1000V
DC Voltage Accuracy
(@60mV-600V) ± 0�5% of rdg + 5D
(@1000V) ± 0�8% of rdg + 4D
DC Current
Ranges: 60A / 600A / 1000A
DC Current Accuracy
± 2�0% of rdg + 8D
AC Voltage
Ranges: 60mV / 600mV / 6V / 60V / 600V / 750V
Frequency Range: 40-400Hz
AC Voltage Accuracy
(@60mV-600V) ± 0�6% of rdg + 5D;
(@750V) ± 0�8% of rdg + 4D
AC Current
Ranges: 60A / 600A / 1000A
Frequency Range:
(@0A - 600A) 40-400Hz
(@600A-1000A) 40-60Hz
AC Current Accuracy
± 2�0% of rdg + 8D
Inrush Current
Ranges: 60A / 600A / 1000A
Frequency Range: 40-400Hz
Inrush Current Accuracy
(@0A-60A) Reference only;
(@600A-1000A) ± 5�0% of rdg + 60D
Resistance
Ranges: 600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ / 60MΩ
Resistance Accuracy
(@600Ω-600kΩ) ± 0.8% of rdg + 3D
(@6MΩ-60MΩ) ± 2.0% of rdg + 5D
Continuity
Meter beeps at < 50Ω
Diode
Forward DC Current: ~ 1mA
Reverse DC Voltage: ~ 3�2V
Capacitance
Ranges: 9�999nF / 99�99nF / 999�9nF /
9.999μF / 99.99μF / 999.9μF / 9.999mF / 99.99mF
Capacitance Accuracy
± 3�0% of rdg + 5D
Frequency
Current Mode Range: 100Hz / 1000Hz
Voltage Mode Range: 100Hz / 1000Hz / 10kHz
Hz/Duty Mode Range: 10Hz / 100Hz / 1000Hz /
10kHz / 100kHz / 1000kHz / 10MHz
Frequency Accuracy
Current Mode: ± 1�5% of rdg + 5D
Voltage Mode: ± 1�5% of rdg + 5D
Hz/Duty Mode: ± 0�3% of rdg + 5D
Duty Cycle
0�1%-99�9%
Duty Cycle Accuracy
± 3�0%
Sampling Rate
~3 samples per second
Operating Temperature
Range: 64�4°F - 82�4°F (18°C - 28°C)
Display
Liquid Crystal Display (LCD)
Battery
9V (Included)