For technical questions, please call 1-888-866-5797.
Item 64017
Sa
F
ety
Opera
ti
O
n
Maintenance
Setup
inrush current
Measure inrush current of AC conductors
carrying up to 1000 amperes�
1� Turn the Rotary Switch to the
60/600
or
1000
position,
depending on the amperage of
the conductor under test�
2� Press
reL/inruSH
for two or
more seconds to switch to
inruSH
current mode�
----
displays while the
inrush current is being detected�
3� Using one hand, press Trigger to
open Current Clamp and insert
conductor inside the jaws�
4� Read measured inrush current
on the Display� The current is
only measured once and the
reading is held on the Display�
5� When testing is complete, turn
Rotary Switch to
OFF,
and store Meter�
note:
If the Display shows
OL
while in
manual range mode, the measurement
has exceeded the selected range� A
higher range should be selected�
ac/Dc Voltage Measurement
Measure AC conductors carrying
up to 750 VAC, 40-400 Hz�
Measure DC conductors
carrying up to 1000 VDC�
WarninG!
Use caution when working
near voltages above 30 VAC rms, 42
VAC peak, or 60 VDC� Voltages this
high present a risk of electric shock�
1� Plug black test lead into
cOM
Jack�
Plug red test lead into
input
Jack�
2� Turn Rotary Switch to the
or
m
position, depending on the
voltage of the conductor under test�
3� Press
Func
button to choose
between AC and DC voltage�
4� Carefully touch exposed
conductors with tips of probes�
5� Read measured voltage on the Display�
6� When testing is complete, turn
Rotary Switch to
OFF
, remove
Test Leads and store with Meter�
note:
If voltage is too high, Meter will beep�