background image

5

START-UP

Warning

At high temperatures, the pump may be extremely hot. Do not  

                touch it.

Priming: 

Before startup, or if the pump has been drained, the pump must be filled with 
liquid and vented. 

Proceed as follows: 

 

Close the discharge isolating valve and bypass valve. 
(See System Design drawing) 

 

Remove the priming plug in the pump sleeve. (See Plug drawing). 

      Slowly open the suction valve (See System Design drawing), in the inlet     
      pipe until a steady stream of liquid runs out of the priming port. 

Warning

The escaping liquid may be very hot. Therefore, care must be  

                  taken to ensure that the liquid does not cause personal injury or 
                  damage to other components

 

Replace priming plug and tighten securely. 

 

Start the pump and slowly open the discharge valve until it is fully open. 

 

Completely open the suction valve in the inlet pipe. 

                                                     Plug Drawing

Summary of Contents for CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM

Page 1: ...N 98 0118 Rev B 28OCT10 CHIE VARIABLE SPEED BOOSTER PUMP SYSTEM OPERATION MAINTENANCE MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 4541...

Page 2: ...STARTUP 5 MAINTENANCE 6 PRELIMINARY CHECKS MEASURING VOLTAGE CURRENT 6 TROUBLE SHOOTING THE PUMP 6 VALVES 6 INDICATOR LIGHTS 7 SETTING BY MEANS OF CONTROL PANEL 8 SETPOINT SETTING PUMP IN CONTROLLED...

Page 3: ...motor and electronics the following must be observed Place the pump in such a way that sufficient cooling is ensured The temperature of the cooling air must not exceed 40 degrees C Cooling fins and fa...

Page 4: ...eakage current 3 5 mA The leakage currents are measured in accordance with EN 60 355 1 8 The motor requires no external motor protection The pump is overvoltage protected 9 Supply voltage 1 x 208 230V...

Page 5: ...r at least 5 minutes Pressure Sensor Installation With the protective cover off bring the wire from the pressure sensor into the motor through the strain relief in the middle Connect the yellow green...

Page 6: ...4 SYSTEM DESIGN DRAWING...

Page 7: ...n the pump sleeve See Plug drawing Slowly open the suction valve See System Design drawing in the inlet pipe until a steady stream of liquid runs out of the priming port Warning The escaping liquid ma...

Page 8: ...sure TROUBLE SHOOTING THE PUMP Before removing the terminal box cover make sure that the electricity supply has been switched off Warning The pumped liquid may be scalding hot and under high pressure...

Page 9: ..._______________________________________________ Permanently Off The pump has stopped because of a fault on Restarting will be attempted it may be necessary to restart the pump by resetting the fault i...

Page 10: ...motor for any length of time may cause burns Only the buttons should be touched to avoid injury The pump control panel incorporates the following buttons and indicator lights CONTROL PANEL The desired...

Page 11: ...ivated indicating a desired setpoint of 3 bar The setting range is equal to the sensor measuring range see sensor nameplate Setpoint set to 3 bar pressure control mode The buttons on the pump control...

Page 12: ...ys By briefly pressing the up or down button on the pump This will not change the setting of the pump A fault indication cannot be reset by means of the up or down button if the buttons have been lock...

Page 13: ...11 REPLACEMENT PARTS DRAWING...

Page 14: ...to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain PVC...

Reviews: