14 //
24
P/N: 630-00047 RevB 11519
Hercules II 600 Vertical Platform Lift Install Manual | www.Ameriglide.com | 866-378-6648
TOP LANDING EMI INTERLOCKS (OPTIONAL)
The optional EMI Interlock is provided with a combination
mechanical lock and electric contact. They are to be used with
existing doors.
The interlock:
•
Prevents the lift from running if the gate is not closed.
•
Prevents the door from being opened if the platform is not at
the landing.
•
Unlocks when the lift is on the landing limit switch.
EMI Interlock
1.
Position interlock to door jamb and mark mounting holes.
2.
Fasten Interlock to door jamb with #8 wood screws.
3.
Route 4-conductor Interlock cable thru hole in top of interlock and make wire connections.
4.
Attach door keeper and emergency key plates to hoistway door.
Wiring
A length of multi-conductor wire will need to be run from the bottom of the lift tower up to the
interlock. Consult local codes for type and mounting requirements. After wiring is completed, the
wiring harness must be plugged into an appropriate receptacle on the controller.
Molex Plug Wiring Connections
EMI
Lift Harness Wires
Black
Orange
Black
Green
Yellow
Black
Yellow
Brown
TOP LANDING EMI INTERLOCKS
TOP LANDING EMI INTERLOCKS
Summary of Contents for AMGHERC600-4