Specifications
GENERAL
Weight:
..............................Digital Clock/Timer ............................... 8.80 lb.
...............................ATSTCS Control Station ........................... 0.27 lb.
External Dimensions:
.........Digital Clock/Timer ............................... 6.1"h x 24"w x 3.5"deep
...............................ATSTCS Control Station ........................... 4.63"h X 4.56"w X 1.25"deep
SPECIFICATIONS
ELECTRICAL
Power Requirements
(Digital Clock/Timer only):
Line Voltage:
..................................................................................... 120vac 50/60Hz -SQA461RS
A
E and SQA461RS
P
E
24vac 50/60Hz - SQA461RS
B
E
220vac 50/60Hz - SQA461RS
K
E
Note: Voltage is set at factory. See above part number suffix for reference.
Battery:
............................................................................................... 9vdc Rechargeable Ni-Cad Battery
Battery Charger:
................................................................................ 9vdc Direct Current source with
current limiting resistor.
Maximum Current
(Digital Clock/Timer only): .................................... 120vac - 130mA (max), 101mA (avg)
Memory Retention on Loss of Line Voltage:
..................................... 4 hours with fully charged battery
Distance of ATSTCS from Digital Clock/Timer:
................................. 30-ft maximum with 22 AWG stranded wire
............................................................................................... with minimum
1
/
32
" thick insulation
Clock Circuits:
................................................................................... 3.0mA. max. @ 24vac/120vac
Code Blue Circuits:
............................................................................ 3.0mA. max. @ 12vac/vdc-30vac/vdc
ENVIRONMENTAL
Ambient Operating Range:
................................................................ 10°C to 49°C (50°F to 120°F)
Recommended Storage Temperature:
.............................................. -30°C to 45°C (-22°F to 113°F)
............................................................................................... for six months maximum
Humidity:
............................................................................................ 85 %RH at 30°C (86°F)
OPERATION
Modes Available:
................12 hour or 24-hour wireless synchronized
Incrementing timer with programmable preset value and start/stop capability
Decrementing timer with programmable preset value and start/stop capability
Code Blue incrementing timer
Accuracy:
.............................................................................±1 second to SiteSync IQ system controller
Indications:
........................Digital Clock/Timer .....................hours and minutes - 4", bright red, seven segment LED’s
hours and minutes are separated by a colon
seconds - 2", bright red, seven segment LED’s
...............................ATSTCS Control Station ..............2 second audible alarm
Reception:
............................................................................Colons flash