Control Station Installation
The ATSTCS Control Station can be mounted to a double gang box, 1
1
/
2
inch deep or deeper. The Control Station can be
mounted up to 30 feet away from the Digital Clock/Timer. The recommended minimum interconnecting field wire size is
#22.8 AWG stranded wire.
Ensure that
installation conforms to the National Electrical Code and local wiring codes.
CAUTION: Electric Shock Hazard!
Ensure that no electrical power is present on any wire before installation.
u
Pull interconnecting field wires into the double gang box.
v
Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock/Timer to the
appropriate wires of the Control Station. See wiring detail below.
w
Mount the Control Station to the double gang box using the machine screws provided.
K2+
K2–
K1+
K1–
12V
AC
12V
AC
UNREG
GND
PIEZ
O
S5
S4
S3
S2
S1
NO
T USED
NO
T USED
RED
BLA
CK
VIOLE
T
GRE
Y
BR
OWN
BL
UE
OR
ANGE
YELL
OW
GREEN
WHITE
PIEZO
BUZZER
RESET
ENTER
START/STOP
INCREMENT
UP
CL
OCK
DOWN
SET
RUN
Green-Earth Gnd
White-Neutral line
Black-Hot line
Digital Clock/Timer
ATSTCS Control Station
20 ft. supplied cable. Can
be extended to 30 ft.
maximum using #22 AWG
wire (min.) with 1/32”
insulation (min.)
Figure 1
Figure 2
6-32 x
3
/
4
black screw
secures device to the
mounting plate
Single or double gang
box (supplied by others)
must be securely mounted
Mounting plate
fastens to the
back box
Mounting plate detail
Typical wiring for the Digital Clock/Timer with Control Station