AllSync IQ Installation Manual
Glossary
Appendix
Tr
oubleshooting
Installation
Intr
oduction
Wired Signal Circuit Option
v
Enabling and Disabling Signal Circuits
u
Setting Signal Circuit Schedule and Duration (continued)
a. From the View Circuits screen, press
3
to enter the Enable Circuits
screen to view or change the control status of individual circuits.
b. For a signal circuit to be controlled by programmed events, it must be
enabled (on) and the status of the system controller must be set to
AUTO. To set status to AUTO:
Press
8
, enter User Lock and press
O
.
c. Setting the system controller status to OFF disables all signal circuits.
To set the status to OFF:
Press
0
, enter the User Lock (unless User Lock is disabled) and press
O
(unless User Lock is disabled)
d. This screen shows the current default duration for all circuits. "<"
indicates an off default and ">" indicates an on default. To change the
default duration for a circuit, press the number of the circuit (i.e.
1
).
e. The Select Circuit Duration screen shows the current default duration
for the selected circuit. This duration applies only for events that are
programmed with a duration of 0. Circuit duration can be for a definite
period (1-9 seconds) or for a time defined by two successive events. The
first event turns the circuit on, the second event turns it off. To change
circuit default duration:
• Press any number 1-9 to specify duration in seconds, or
• Press
>
to latch the circuit on, or
• Press
<
to latch the circuit off.
Pressing any of these options saves the circuit duration and returns to
the View Circuits screen (
a
).
To see a programming example, see Appendix D.
Circuit Menu
Select Cir 1 Duration
5 Sec (1-9, <or>)
Latchin Off=< On=>
Circuit Menu
Select Circuit:
Cir 1 2
Dur < 1
1e
1d
Circuit Menu
Enable Cir: OK=Done
1=On 2=On 3=On
4=On 5=On 6=On
Circuit Menu
View Circuits for:
1=Schedule 3=On/Off
2=Duration Prog=Exit
2b
2a
1:49
FRI OCT 3 2014
:45
AM