Mark two mounting holes using new wall plate.
c. Pull wires through hole in center of wall plate.
d. Locate the new wall plate over existing opening.
e. Mark two holes with pencil.
f.
Use a level to verify that the two hole locations are level.
g. Correct hole locations as needed.
6
Prepare two mounting holes.
h. Drill 1/16” pilot holes in the two locations that were marked in step 9. If mounting to drywall with no
studs behind it, enlarge pilot holes to 1/8” for anchors (included with the thermostat).
i.
If using anchors, screw them into the holes.
8
Attach all wires securely to the new thermostat.
(See the Field Wiring Diagrams on the following page.)
Note: A wire must be connected to “24COM” to power the thermostat.
a. Use the information from the Field Wiring Diagrams to match the wires to the correct terminals.
b. Use 1/8” blade screwdriver to secure wires in terminals.
CAUTION: EQUIPMENT DAMAGE HAZARD
Improper wiring can lead to equipment damage. Follow the Terminal Connection information from step 6
carefully to ensure the control is wired properly. After wires are secure, bare wires MUST NOT touch each
other. See the Field Connection Wiring Diagrams on the following pages for specific system applications.
7
Install new wall plate.
c. Pull wires through hole in center of wall plate.
d. Locate the new wall plate over existing opening.
e. Attach wall plate to wall using two screws provided. Do not overtighten.
Anchors
Wall plate
24RC
G
Y1
Y2
RS
2
RS
2
24C
24RH
W1
W2/O
RS
1
RS
2
Shld
HC
Shld
H1
24RC
G
Y1
Y2
RS
2
RS
2
24C
24RH
W1
W2/O
RS
1
RS
2
Shld
HC
Shld
H1
24RC
G
Y1
Y2
RS
2
RS
2
24C
24RH
W1
W2/O
RS
1
RS
2
Shld
HC
Shld
H1
4
Separate the face of the new thermostat from the wall plate.
Apply pressure at two tabs on top of wall plate to release it.
Î
NOTE: It is not recommended that this Z-wave
TM
thermostat be mounted onto metal structures.
Metal may adversely affect the radio frequency (RF) communication between the thermostat and the
Z-wave
TM
bridge.
3
Remove existing wall plate.
Î
Note: During this process, make sure that the wires do not pull back into wall opening.
a. Detach all wires from wall plate.
b. Remove all screws attaching the wall plate to the wall and remove wall plate.
Î
See
Mercury Notice on page .