Prepare the bridge for enrollment.
Î
Note: If the bridge is already installed, follow the instructions as they are
written in the following steps. If the bridge is not installed, follow the Quick
Start Guide publication number shipped with the thermostat starter kit.
a. Unplug Ethernet and power cables from bridge.
b. Install a quality 9 volt battery.
c. Verify that blue light is blinking. If blue light is solid, battery is dead.
d. Take bridge to the location where the thermostat is mounted.
Blue
light
Battery
Enroll Thermostat into existing Schlage LiNK™ System
18
Enroll the thermostat into the bridge. (Inclusion)
If you are using a controller that is not a Schlage LiNK
TM
bridge, consult the Quick
Start Guide that came with the controller to find out how to enroll a new device.
a. Hold the bridge within 6 feet (1.8 meters) of the thermostat throughout steps
“b” through “f”.
Î
After you begin the enrollment process, you have 30 seconds to complete
the remainder of the steps. Study the steps below before beginning.
b. Press and release the plus (+) button on the bridge.
c. Press the MENU button on the thermostat.
d. Scroll down to Z Wave Install, and press the Select button.
e. Press the Yes button to enroll the thermostat.
f.
Observe the lights on the bridge. The orange light will blink while enrollment
is taking place. Enrollment is complete when the orange light becomes solid.
MENU button
MENU MODE FAN RUN
75
76 H
74 C
11:15 AM
Gat
ew
ay
24RC
G
Y1
Y2
RS2
RS2
24C
24RH
W1
W2/O
RS1
RS2
Shl
d
H1
Shl
d
H2
“+” Button
19
Verify enrollment of the thermostat.
a. Scroll down to
Thermostat Info, and press the Select button.
b. Look at the number listed after
ZNID.
• If the number listed there is anything other than “000”, the
thermostat has been successfully enrolled.
• If the number listed there is “000”, the thermostat has NOT
been successfully enrolled. In this case, repeat step 22 and
verify again.
c. Press Done button 2 times when finished.
Item
Description
AZEMT500BB32
Model Number
Ver: 01.00.13
Firmware version (number may vary)
ZVER: 02.00.9
Z-Wave version (number may vary)
ZNID: 013
Z-Wave node ID (number may vary)
ZHID: 01.07.37.a7
Z-Wave Home ID (number may vary)
System Type: Standard
System type may be Standard or Heat Pump
Fan Type: Gas
Fan type may be Gas or Elect (electric)
ZNID
Done
Thermostat Info
AZEMT500BB32 Ver: 01.00.13
ZVER:02.00.0 ZNID: 013
ZHID: 01.07.37.a7
System Type: Standard
Fan Type: Gas
Done
Select
Menu Selection
User Settings
Usage Graph
ESM Setpoints
ZWave Install
Select button
Scroll