6

M965652 Rev. 1.9 (3/19)

Fig. 2

  2

  3

1

Fig. 2a

16

6

9

8

10

2

PLUG INTO

WALL OUTLET

7

Fig. 2c

BLACK & WHITE

POWER

CONNECTIONS

10' EXTENSION

13

12

10b

15

14

10a

7

2

2

Fig. 2b

6

9

FROM ELECTRICAL BOX

WITH POWER SUPPLY

16

B

    AC VERSION; Fig. 2 

• 

PLUG-IN 

 HARDWARE

Note:  For AC installation, make power supply connection 

before mounting CONTROL BOX (3) to wall.

1.

  

  Remove CONTROL BOX COVER 

(1)

. Feed the  

  CABLES 

(2)

 from the Faucet through the top of 

 

  ENCLOSURE 

(3)

FOR AC PLUG-IN ONLY

2a.

  

Insert POWER CORD

 (8) 

through POWER SUPPLY 

GROMMET

 (9)

.

 Fig. 2a.

3a.

  

Insert POWER CORD 

(8)

 through side GROMMET

 (6) 

 

as shown. 

Fig. 2a.

4a. 

 Connect

 one of the CABLES 

(2)

 to 

 SOLENOID CABLE 

(7 

 

and the other to the SINGLE AC ADAPTER

 (10)

. Connect 

 POWER CORD 

(8)

 to Single AC  Adapter 

(10)

 and install 

 CONNECTOR LOCKING DEVICE 

(16)

Fig. 2a

.

5a.

  Mount 

CONTROL BOX

 to wall. Replace 

CONTROL BOX

 

COVER 

(1)

. Tighten cover screws firmly.

6a.

  

Plug AC POWER SUPPLY into wall outlet.

FOR HARDWIRE HOOK-UP ONLY

2b.

  

Insert one end of the 10

'

 EXTENSION 

(10a)

 through  

POWER SUPPLY GROMMET 

(9)

Fig. 2b.

3b.

  Insert 10

'

 EXTENSION

 (10a) 

through side  

GROMMET

 (6)

 as shown. 

Fig. 2b.

4b.

  

Connect CABLES 

(2) 

to SOLENOID CABLE

 (7)

 and the 

other to the 10' EXTENSION CABLE 

(10a)

.  Install  

CONNECTOR LOCKING DEVICE 

(16)

Fig. 2b.

Contractor to supply ELECTRICAL BOX (12) and power  
to POWER SUPPLY (13).
5b.

  

Mount POWER SUPPLY

 (13) 

onto ELECTRICAL 

 

BOX

 (12)

. Connect connections to POWER SUPPLY 

 

CONNECTIONS 

(14). Fig. 2c.

6b.

  Connect the10

'

 EXTENSION 

(10b)

 to the POWER 

 

SUPPLY CABLE

 (15)

Fig. 2c.

CAUTION

Disconnect AC power supply  

before opening CONTOL BOX.

CAUTION:

 Use only American Standard supplied cable sets. 

Using non-AS supplied cables, or cutting, splicing or modifying 

any components will void the warranty.

Summary of Contents for Innsbrook SELECTRONIC 605 202 Series

Page 1: ...our website at www americanstandard us com or e mail us at CRTTEAM lixilamericas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In T...

Page 2: ...LM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 1 Installation Instructions SELECTRONIC Hard Wired AC Powered Innsbrook Lavatory Proximity Faucet MODEL NUMBERS 605X 202 605X 204 605X 205 ASME A112 1...

Page 3: ...CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty 1 INSTALL SPOUT ASSEMBLY Fig...

Page 4: ...HOSETO CONTROL BOX Fig 3 1 Connect SUPPLY NUT 1 from spout hose to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 4 CONNECT WATER SUPPLY TO CONTROL...

Page 5: ...ugh side GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to CABLES 2 Place Standard Battery or PWRX Battery Pack into housing Fig 1d 6 Reinstall CONTROL BOX COVER 1 Tight...

Page 6: ...ll CONNECTOR LOCKING DEVICE 16 Fig 2a 5a Mount CONTROL BOX to wall Replace CONTROL BOX COVER 1 Tighten cover screws firmly 6a Plug AC POWER SUPPLY into wall outlet FOR HARDWIRE HOOK UP ONLY 2b Insert...

Page 7: ...SOLENOID CABLE 7 and the other to either of the two available terminals of the Y ADAPTER 11 Connect the current unit s 10 EXTENSION 10a to available terminal of the Y ADAPTER 11 5 Feed the other end...

Page 8: ...n and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection dist...

Page 9: ...nserted first and shape of the battery follows the shape of the BATTERY HOLDER 3 4 To replace PWRX BATTERY PACK 4 unplug and replace with new Power Pack 5 Reconnect BATTERY HOLDER 3 to CABLE 5 6 Reins...

Page 10: ...etergents or chemicals FAQ S Q How will I know if the battery needs to be replaced A Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has th...

Page 11: ...NO FULLY OPEN INTERNAL EXTERNAL SUPPLY STOPS BY TURNING COUNTER CLOCKWISE LOW FLOW COULD BE CAUSED BY DEBRIS IN THE FILTER ASSEMBLY FLOW REGULATOR OR AERATOR SPRAY REMOVE CLEAN AND INSERT BACK TO ORI...

Reviews: