American Standard Innsbrook SELECTRONIC 605 202 Series Installation Instructions Manual Download Page 9

9

M965652 Rev. 1.9 (3/19)

Fig. 4

CR-P2

6

3

2

STANDARD

BATTERY

PWRX

4

1

5

2

3

Fig.5

1

Fig.5

D

     INSTALL / REPLACE  THE BATTERY  

or PWRX; Fig. 4

1.

   

Remove COVER from CONTROL BOX 

(1)

2.

  

Disconnect BATTERY HOLDER 

(3)

 from CABLE 

(5)

.

3.

  

Remove old BATTERY from Battery Holder 

(3)

.  Install new 

BATTERY 

(2)

 making sure the terminal side  is inserted first 

and shape of the battery follows the shape 

 

of the BATTERY 

HOLDER

 (3)

.

4.

  

To replace PWRX BATTERY PACK

 (4)

, unplug and   replace 

with new Power Pack.

5.

 Reconnect BATTERY HOLDER 

(3)

 to 

CABLE

 (5)

.

6.

  

Reinstall CONTROL BOXT COVER. Tighten cover 

 

screws firmly.

E

    CLEAN AND REMOVE THE AERATOR; Fig. 5

1. 

 

Remove AERATOR HOUSING 

(1)

 with KEY supplied 

      

with faucet.

2.

 Remove AERATOR

 (2)

 from HOUSING 

(1)

.

3.

 Clean the AERATOR SCREENS

 (3)

.

4.

  Clean with water. Reassemble and install into spout end. 

Make sure black seal washer is in place..

Summary of Contents for Innsbrook SELECTRONIC 605 202 Series

Page 1: ...our website at www americanstandard us com or e mail us at CRTTEAM lixilamericas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In T...

Page 2: ...LM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 1 Installation Instructions SELECTRONIC Hard Wired AC Powered Innsbrook Lavatory Proximity Faucet MODEL NUMBERS 605X 202 605X 204 605X 205 ASME A112 1...

Page 3: ...CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty 1 INSTALL SPOUT ASSEMBLY Fig...

Page 4: ...HOSETO CONTROL BOX Fig 3 1 Connect SUPPLY NUT 1 from spout hose to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight connection Fig 3 4 CONNECT WATER SUPPLY TO CONTROL...

Page 5: ...ugh side GROMMET 6 as shown Fig 1c 5 Connect SOLENOID CABLE 7 and BATTERY CONNECTOR 5a to CABLES 2 Place Standard Battery or PWRX Battery Pack into housing Fig 1d 6 Reinstall CONTROL BOX COVER 1 Tight...

Page 6: ...ll CONNECTOR LOCKING DEVICE 16 Fig 2a 5a Mount CONTROL BOX to wall Replace CONTROL BOX COVER 1 Tighten cover screws firmly 6a Plug AC POWER SUPPLY into wall outlet FOR HARDWIRE HOOK UP ONLY 2b Insert...

Page 7: ...SOLENOID CABLE 7 and the other to either of the two available terminals of the Y ADAPTER 11 Connect the current unit s 10 EXTENSION 10a to available terminal of the Y ADAPTER 11 5 Feed the other end...

Page 8: ...n and hold in place until the LED begins to blink again Fig 2a 4 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection dist...

Page 9: ...nserted first and shape of the battery follows the shape of the BATTERY HOLDER 3 4 To replace PWRX BATTERY PACK 4 unplug and replace with new Power Pack 5 Reconnect BATTERY HOLDER 3 to CABLE 5 6 Reins...

Page 10: ...etergents or chemicals FAQ S Q How will I know if the battery needs to be replaced A Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has th...

Page 11: ...NO FULLY OPEN INTERNAL EXTERNAL SUPPLY STOPS BY TURNING COUNTER CLOCKWISE LOW FLOW COULD BE CAUSED BY DEBRIS IN THE FILTER ASSEMBLY FLOW REGULATOR OR AERATOR SPRAY REMOVE CLEAN AND INSERT BACK TO ORI...

Reviews: