ACONT900AC43UA
Pub. No. 11-HD04D1-2
69-2080—05
14
Minimum
Compressor On Time
0630
3
0 - 15
Minimum number of
minutes compressor is on.
Clock Format
0640
12
12, 24
12 - 12-hour clock format
24 - 24-hour clock format
Extended Fan On
Time Heat
0650
0
0, 30, 60,
90 or 120
Fan operation is extended
0, 30, 60, 90 or 120
seconds after call for heat
ends.
Only shown for nonvariable
speed indoor units.
Compressor Heat
Blower Off Delay
Profile
0651
5
0 - 5
0 - Disabled
1 - 0.5 min @ 35%
2 - 0.5 min @ 50%
3 - 1.5 min @ 50%
4 - 0.75 min @ 100%
5 - 1.5 min @ 100%
Only shown for variable
speed indoor units.
Extended Fan on
time control
0660
90
0, 30, 60,
90 or 120
Fan operation is extended
0, 30, 60, 90 or 120
seconds after call for cool
ends.
Only shown for nonvariable
speed indoor units.
Compressor Cool
Blower Off Delay
Profile
0661
5
0 - 5
0 - Disabled
1 - 0.5 min @ 35%
2 - 0.5 min @ 50%
3 - 1.5 min @ 50%
4 - 0.75 min @ 100%
5 - 1.5 min @ 100%
Only shown for variable
speed indoor units.
Compressor Heat
Fan On Delay Profile
0665
0
0, 1, 5,
10, 20,
30
0 - Disabled
1 - Enabled - 50% for 1
minute (V.S. only)
5 - 5 seconds
10 - 10 seconds
20 - 20 seconds
30 - 30 seconds
For Variable Speed indoor
units: choices are 0 and 1.
For Non-variable Speed
indoor units: choices are 0,
5, 10, 20, and 30.
Compressor Cool
Fan On Delay Profile
0667
0
0, 1, 5,
10, 20,
30
0 - Disabled
1 - Enabled - 50% for 1
minute (V.S. only)
5 - 5 seconds
10 - 10 seconds
20 - 20 seconds
30 - 30 seconds
For Variable Speed indoor
units: choices are 0 and 1.
For Non-variable Speed
indoor units: choices are 0,
5, 10, 20, and 30.
Keypad Lockout
0670
0
0, 1, 2
0 - Unlocked keypad
1 - Partially locked keypad
2 - Fully locked keypad
Unlocked - all functions are
available.
Partially locked - only
temperature up and down
keys and ability to enter and
modify installer setup mode
are available.
Fully locked - only ability to
enter and modify installer
setup mode are available.
Temperature Control
in Heat
0680
2
1, 2, 3
1 - Less aggressive
temperature control (could
cause temperature
undershoot)
2 - Standard temperature
control in heating
3 - More aggressive
temperature control (could
cause temperature
overshoot)
Applies to recovery ramp
and use of auxiliary heat
during recovery.
Table 4. Installer Setup Menu
Selection
Installer Setup
Number (ISU)
Factory
Setting
Choices
Comments
Option
Description