ACONT900AC43UA
Pub. No. 11-HD04D1-2
69-2080—05
12
Dehumidification
Airflow
0387
100
80 - 100
80 - 80% Airflow
85 - 85% Airflow
90 - 90% Airflow
95 - 95% Airflow
100 - 100% Airflow
Only shown for variable
speed indoor units. See
Advanced Features section
for more information
American Standard
Heating & Air
Conditioning
Proprietary Humidity
Control
0388
1
0, 1
0 - Disabled
1 - Enabled
Not shown if ISU0380 is set
to 0.
See Advanced Features
section for more information
Furnace Filter 1
Change Reminder
0500
E, 0
E, 0 - 14 E - Auto-Discover
0 - Disabled (reminder off)
1 - 10 run time days
2 - 30 run time days
3 - 60 run time days
4 - 90 run time days
5 - 120 run time days
6 - 180 run time days
7 - 270 run time days
8 - 365 run time days
9 - 30 continuous days
10 - 60 continuous days
11 - 90 continuous days
12 - 120 continuous days
13 - 180 continuous days
14 - 365 continuous days
When set to Auto-Discover
(and the discovered value is
not 0=disabled), the
Comfort Control will display
the filter timer value it
receives from the
AccuLink
TM
communicating
filtering device on the More
screen.
To reset the filter timer of
the AccuLink
TM
communicating filtering
device, simply press the
More key to access the filter
timer value and then press
the Reset key. If no
AccuLink
TM
communicating
filtering device has been
discovered, the auto-
discovered value will default
to 0.
When not set to Auto-
Discover (and not set to
0=disabled), the Comfort
Control will display its
internal filter timer on the
More screen.
To reset the Comfort
Control's internal timer,
simply press the More key
to access the filter timer
value and then press the
Reset key.
Table 4. Installer Setup Menu
Selection
Installer Setup
Number (ISU)
Factory
Setting
Choices
Comments
Option
Description