background image

7

4580 N. Walnut Rd., N. Las Vegas, NV 89081    |    13592 Desmond St., Pacoima, CA 91331    |    tel: 818.897.0808    |    888.753.9898    |    www.AmericanRangeHome.com

INSTALLATION

CHECK THAT ALL GAS CONNECTIONS ARE PROPERLY SEALED WITH A SUITABLE GAS JOINT COMPOUND.

TEST ALL JOINTS WITH A SOAPY WATER SOLUTION BEFORE LIGHTING THE BURNERS.

1.  Turn ON the manual gas valve at the inlet side of the gas supply line.

2.  Check for gas leaks at the flexible coupling or gas connector fitting using a solution of one part soap and three parts water.

3.  Sparingly spray or brush the soapy solution at the gas fittings; active bubbling indicates location of gas leak.

4.  If a gas leak is detected turn off the manual gas valve at the inlet side of the gas line. Call your certified service technician.

 

»

Do not remove protective packaging until you are ready to 
perform the installation.

 

»

Caution – the appliance is heavy. Use extreme care when 
handling!

 

»

Any openings in the wall and in the floor behind or under the 
cooktop must be sealed.

 

»

Do not use an extension cord with this appliance. Such use 
may result in fire, electrical shock or other personal injury.

INSTALLATION

The location selected for the range must meet the following 

criteria. If any of these criteria are not met, select another 

location.

SITE PREPARATION

 

»

The cooktop is zero-clearance safe against non-combustible 
surfaces

 

»

The maximum depth of overhead cabinets installed on either 
side of the hood is 13"

 

»

Any openings in the wall behind the range and in the floor 
under the range must be sealed

ELECTRICAL CONNECTION

 

»

The cooktop must be electrically grounded in compliance with 
local codes or, in the absence of local codes, with the National 
Electrical Code, ANSI/NFPA70.

 

»

This cooktop requires a 120 volt supply to operate the ignition 
system. The supply cord provided on the range is equipped 
with a three-prong (grounding) plug for protection against 
electrical shock.

 

»

The electrical service in the building must be equipped with a 
properly grounded three-prong receptacle.

 

»

Do not cut or remove grounding prong from this plug.

POWER REQUIREMENTS FOR THIS COOKTOP

 

»

120 VAC, 60 Hz, single phase, 15 AMP Max

GAS CONNECTION

 

»

Be certain the appliance being installed is correct for the gas 
service being provided. Refer to the appliance data plate for the 
gas supply requirements.

 

»

A manual gas shut-off valve must be remotely installed and 
easily accessible within the cabinet. The regulator inlet is for a 
1/2 inch gas line. The appliance ships with a 1/2 inch regulator.

 

»

Use at least a 1/2" commercial flex hose to connect range to 
the gas supply (service line).

 

»

A manual gas shut-off valve must be installed, in easy access in 
front of the gas supply (service line) and ahead of the cooktop 
for safety and ease of maintenance.

 

»

All valves must be in the OFF position before connecting to the 
gas supply line.

PRESSURE REGULATOR

 

»

  The regulator packed with the cooktop is adjusted at the 
factory for 5" WC (natural gas) or 10" WC (L.P.)  depending 
on the customer’s request. Regulators must be used in the 
installation.

 

»

The regulator can withstand a maximum pressure of 1/2 PSIG 
(14" WC). If the line pressure is beyond this limit, a step-down 
regulator will be required. 

 

»

Any adjustment to regulators must be made ONLY BY 
QUALIFIED service personnel with proper test equipment.

GAS REQUIREMENTS

 

»

Ensure supplied gas matches the cooktop’s gas type.

 

»

Natural gas connection is 1/2" N.P.T. minimum 1/2" diameter 
flex line.

 

»

Natural gas inlet pressure to measure 7" to 10" W.C.

 

»

Propane gas connection is 1/2" N.P.T. minimum 1/2"  diameter 
flex line.

 

»

LP gas inlet pressure to measure 11" to 14" W.C.

 

»

A step-down regulator in addition to the regulator provided    
with the LP range is required at the LP (Propane) source to    
limit pressure to a maximum of 14" W.C.

 

»

Installation of this appliance should be performed by qualified, 
licensed contractors.

 

»

To remove the packaging, first remove the staples located at 
the bottom perimeter of the corrugated cardboard cover.

 

»

Confirm access to adequate power and gas. See specifications 
and electrical requirements table.

 

»

Fill out the inside cover of this installation manual with the 
requested data. Model Number and Serial Number can  
be found on the plate located on the bottom of the chassis.

Summary of Contents for VITESSE ARDCT-305

Page 1: ...nge for broil or bake and how to use convection to speed cooking times and improve the quality of your baked and roasted dishes Care and Cleaning discusses how to keep your product in good operating c...

Page 2: ...upplier Please ensure that the product is properly grounded In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Your safety and the safety of others...

Page 3: ...y materials that will not discolor or delaminate and will withstand temperatures up to 194 F 90 C Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry check wi...

Page 4: ...nce of local codes this appliance must be installed in accor dance with the National Fuel Gas Code No Z223 1 current issue and the National Electrical Code ANSI NFPA No 70 current issue or the CAN B14...

Page 5: ...erations and the possibility of personal injury when applicable do not attempt to light or operate range burners grills griddles the oven or broiler during a power failure Safety systems which detect...

Page 6: ...ed to be child safe however they are not a guarantee of operation Children must not be left alone or unattended in the kitchen while the appliance is in use Never leave the appliance unattended during...

Page 7: ...cut or remove grounding prong from this plug POWER REQUIREMENTS FOR THIS COOKTOP 120 VAC 60 Hz single phase 15 AMP Max GAS CONNECTION Be certain the appliance being installed is correct for the gas se...

Page 8: ...MODEL ARDCT 305 ARDCT 365 ARDCT 366 B 30 36 36 MODEL ARDCT 305 ARDCT 365 ARDCT 366 A 29 35 35 OVERALL CUTOUT VENT HOOD CLEARANCE DIMENSIONS VENT HOOD RECOMMENDATIONS COOKTOP MODEL WALL MOUNT INSTALLA...

Page 9: ...______________________________ __________________________________________________________ __________________________________________________________ ___________________________________________________...

Page 10: ...R17598 1 3 Grate Center R17595 1 SINGLE BURNER 4 Burner Caps R16403 4 3 4 5 Burner Head R16404 4 3 4 FIXED TOWER BURNER 6 Burner Caps Front Left R16407 1 1 DUAL BURNER 7 Base Dual Burner Inner R16419...

Page 11: ...Knobs with Simmer 2 2 Single Burner Knobs 3 3 Grates 3 ARDCT 366 1 Dual Burner Knobs with Simmer 2 2 Single Burner Knobs 4 3 Grates 3 ARDCT365 Single Burner Knobs Dual Burner Knobs Single Burner Knob...

Page 12: ...ration This will disappear with continued use Small yellow tips on the ends of flames are normal when using LP gas If the flames look odd too small too large lazy or drifting uneven around the burner...

Page 13: ...iting the burners Push the knob in and turn it counter clockwise to the HIGH position Adjust the flame to the desired height The burners are equipped with a flame sensing ignition system that automati...

Page 14: ...e on position Gas supply has been interrupted Contact the gas company Ignitors Keep Clicking Reverse polarity of the electrical supply line Check the polarity with a hand held tester Poor electrical g...

Page 15: ...imitation of Warranty AMR shall have no obligation under this Warranty as to any Product s which have been misapplied mishandled abused misused modified altered subject to improper cleaning methods su...

Page 16: ...warranty period the receipt proving certified installation must be made available to American Range for verification If installation was not performed by a certified licensed contractor be prepared t...

Reviews: