background image

  KOBE Range Hoods 

 

Brillia Series 

 
 

Model No.:   

Under Cabinet:  RAX2830SQB-2 (30”) 

RAX2836SQB-2 (36”) 

Wall Mount:  RAX2830SQB-WM-2 (30”) 

RAX2836SQB-WM-2 (36”) 

 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 

INSTALLATION INSTRUCTIONS 

AND OPERATION MANUAL

Summary of Contents for RAX2830SQB-2

Page 1: ...KOBE Range Hoods Brillia Series Model No Under Cabinet RAX2830SQB 2 30 RAX2836SQB 2 36 Wall Mount RAX2830SQB WM 2 30 RAX2836SQB WM 2 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL ...

Page 2: ...OT INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shipping damages cosmetic damages or defects 4 For all other issues call 1 877 BUY KOBE 289 5623 or e mail to info koberangehoods com NO RETURN NO REFUND NO EXCHANGE IF 1 PRODUCT HAS BEEN INSTALLED 2 KN...

Page 3: ...CE 12 SPECIFICATIONS 13 MEASUREMENTS DIAGRAMS 14 PARTS LIST 16 CIRCUIT DIAGRAM 18 TROUBLE SHOOTING 19 WARRANTY 20 WARRANTY INFORMATION FORM 22 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S ...

Page 4: ...eatment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hoo...

Page 5: ...you still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk of fire use only metal ductwork Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney to prevent back drafting 3 Follow the heating equipment manufacturer s...

Page 6: ...nge Hood B Warranty Registration Card C Quick Reference Guide D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Wire Cap x 3 G Screws Package A B C D Knob is attached to baffle filter E Pre installed F G FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www koberangehoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 Wire caps 3 M4 x 1 1 2 4 ...

Page 7: ... Guide D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Duct cover Mounting Bracket G Adjustable Duct Cover H Screws Package I Wire Cap x 3 J Screws Package A B C D Knob is attached to baffle filter E Pre installed F G H I J FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE www koberangehoods com OR CONTACT KOBE RANGE HOODS AT 626 775 8880 3 16 x 3 8 8PCS Wire caps 3 M4 x 1 1 2 4 ...

Page 8: ...ling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABLE 2 A Height of Floor to Ceiling B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of Duct Cover F D F Height of...

Page 9: ...Y SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Contents UNDER THE CABINET WALL MOUNT 7 9 ...

Page 10: ...e and create access opening for electrical wires and exhaust under the cabinet Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE And use a protective covering to prot...

Page 11: ...ICAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY If hood is operating normally connect three wires black white and green to house wires and cap with wire connectors Store wires in the wiring box Install Uninstall Accessories 6 Place baffle filters underneath the hood Figure 7 Final Assembly 7 Turn power...

Page 12: ...allation Using references on Table 2 and measurements on page 14 15 decide the level of the lumber Refer to Figure 9 Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If moving the cooking range is necessary to install the hood turn off the power in an electric range at the main electrical box SHUT OFF THE GAS BEFORE MOVING A GAS RANGE...

Page 13: ...k the position of the Duct Cover Mounting Bracket F Use reference E from Table 2 and measurements on page 14 15 Attach and secure Duct Cover Mounting Bracket F with two screws provided Refer to Figure 12 NOTE Inner duct cover will cover the Duct Cover Mounting Bracket 6 Remove the Baffle Filters Position the entire duct cover up onto the hood and secure with six 3 16 x 3 8 screws H from inside the...

Page 14: ...ff Control is turned on the prior fan selection will turn on Press the Speed Controls Low High or QuietMode to select the desired speed QuietMode supersedes all other fan control Turn off QuietMode to use Low or High speed Press On Off Control to turn fan off To operate the light function Press On Off Control to turn on the power Press the Light Control to turn lights on and off Note The Power Con...

Page 15: ...born spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting 5 DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals ...

Page 16: ... x 2 HOOD DIMENSION W x D x H RAX2830SQB 2 and RAX2830SQB WM 2 29 3 4 x 19 5 8 x 11 5 8 RAX2836SQB 2 and RAX2836SQB WM 2 35 3 4 x 19 5 8 x 11 5 8 OPTIONAL ACCESSORIES W x D x H 1 30 Stainless Steel Back Panel SSP30 30 x 1 10 x 32 2 36 Stainless Steel Back Panel SSP36 36 x 1 10 x 32 HOOD WEIGHT lbs Net Gross RAX2830SQB 2 30 33 40 RAX2836SQB 2 36 36 44 RAX2830SQB WM 2 30 43 50 RAX2836SQB WM 2 36 46 ...

Page 17: ...measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO RAX2830SQB 2 30 RAX2836SQB 2 36 FOR WALL MOUNT MODEL NO RAX2830SQB WM 2 30 RAX2836SQB WM 2 36 ...

Page 18: ...15 Hood Mounting Bracket Duct Cover Mounting Bracket ...

Page 19: ...1 0401 0120 04 3 LED Light Driver L1 0402 D001 4 Capacitor Box L1 0524 0003 5 LED Light 3W x 2 L1 0403 0301 6 Control Panel Support L1 0207 2830 7 ON OFF Switch L1 0405 0101 8 Speed Switch I II L1 0405 0103 9 Speed Switch Q L1 0405 0104 10 Light Switch L1 0405 0102 11 Motor Bracket L1 0105 2830 12 Blower system L1 0302 0120 101RO 13 Baffle Filter L1 0214 0122 ...

Page 20: ...ht Driver L1 0402 D001 6 Capacitor Box L1 0524 0003 7 LED Light 3W x 2 L1 0403 0301 8 Control Panel Support L1 0207 2830 9 ON OFF Switch L1 0405 0101 10 Speed Switch I II L1 0405 0103 11 Speed Switch Q L1 0405 0104 12 Light Switch L1 0405 0102 13 Motor Bracket L1 0105 2830 14 Blower system L1 0302 0120 101RO 15 Baffle Filter L1 0214 0122 MODEL NO Wall Mount RAX2830SQB WM 2 30 RAX2836SQB WM 2 36 ...

Page 21: ...18 CIRCUIT DIAGRAM MODEL NO RAX2830SQB 2 30 RAX2836SQB 2 36 RAX2830SQB WM 2 30 RAX2836SQB WM 2 36 ...

Page 22: ...ctive Replace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel or LED light driver is defective Replace the control panel or LED light driver The range hood is not venting out correctly The range hood is installed outside of the manufacture recommended clearance Adjust the clearance between the range hoo...

Page 23: ...ited States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited There may be additional shipping charges for parts and service technician travel costs in remote areas or locations 30 miles outside of KOBE authorized service area WHAT IS NOT COVERED 1 Normal wear and...

Page 24: ...service you will be responsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY SERVICE PLEASE CONTACT KOBE RANGE HOODS SERVICE CENTER From the 48 contiguous states Toll Free 1 877 BUY KOBE 289 5623 E Mail customer service koberangehoods com From Alaska Hawaii and Canada TEL 1 ...

Page 25: ...e 1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com For service in Canada and to report a problem please contact Phone 1 626 775 8880 Email customer service koberangehoods com Your notes ...

Page 26: ... utiliser cette hotte à l étranger puisque l alimentation électrique pourrait ne pas être compatible et enfreindre le code de l électricité de ce pays L usage de la hotte KOBE à l étranger est à votre propre risque et la garantie sera annulée Esta campana de extracción KOBE ha sido fabricada para ser utilizada únicamente en EE UU y CANADÁ No recomendamos la utilización de esta campana en el extran...

Reviews: