The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI. 
 
The gas supply line must be at least the same size as the gas inlet of the appliance. 

 

Clearances 

 

Non-combustible Walls 
 

 

Combustible Walls 
 

 

Rear 

 

Sides 

 

Rear 

 

Sides 

ARMG, ARTG, ARHP 

0” 

0” 

 

7” 

8” 

ACB 

0” 

0” 

 

4” 

4” 

ARRK, ARKB 

0” 

0” 

 

16” 

16” 

ARSP, ARCR 

0” 

0” 

 

N/A 

N/A 

 

For installation on a non-combustible counter/floor only. 

 

OPERATING INSTRUCTIONS 

 

Before lighting, check all joints in the gas supply line for leaks. DO NOT USE OPEN FLAME TO CHECK FOR 

FLAMES! USE SOAP AND WATER SOLUTION. 

 

Lighting and Shut Down 

 

1.

 

Turn all valves to “OFF” position. 

2.

 

Wait five minutes. 

3.

 

Turn pilot valve(s) adjusting – screw counter-clockwise, then light standing pilot and adjust flame1/4” inch 
high. 

4.

 

Turn “ON” gas valve(s) to light main burners. 

5.

 

For complete shut down, shut off gas valve(s) and turn pilot valve(s) adjusting – screw clockwise to shut 
off gas to the pilot(s). 

 

Lighting and Shut Down (ACB Series) 

 

1.

 

Turn all valves to “OFF” position. 

2.

 

Wait five minutes. 

3.

 

Turn gas valve handle to pilot position. Depress the button and light pilot. Hold button for 30 to 40 

seconds until the pilot stays lit. 

4.

 

If pilot goes out, repeat steps 1 – 3. 

5.

 

Turn “ON” gas valve(s) to light main burners. 

6.

 

For complete shut down, shut off gas valve. 

 

 