The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least the same size as the gas inlet of the appliance.
Clearances
Non-combustible Walls
Combustible Walls
Rear
Sides
Rear
Sides
ARMG, ARTG, ARHP
0”
0”
7”
8”
ACB
0”
0”
4”
4”
ARRK, ARKB
0”
0”
16”
16”
ARSP, ARCR
0”
0”
N/A
N/A
For installation on a non-combustible counter/floor only.
OPERATING INSTRUCTIONS
Before lighting, check all joints in the gas supply line for leaks. DO NOT USE OPEN FLAME TO CHECK FOR
FLAMES! USE SOAP AND WATER SOLUTION.
Lighting and Shut Down
1.
Turn all valves to “OFF” position.
2.
Wait five minutes.
3.
Turn pilot valve(s) adjusting – screw counter-clockwise, then light standing pilot and adjust flame1/4” inch
high.
4.
Turn “ON” gas valve(s) to light main burners.
5.
For complete shut down, shut off gas valve(s) and turn pilot valve(s) adjusting – screw clockwise to shut
off gas to the pilot(s).
Lighting and Shut Down (ACB Series)
1.
Turn all valves to “OFF” position.
2.
Wait five minutes.
3.
Turn gas valve handle to pilot position. Depress the button and light pilot. Hold button for 30 to 40
seconds until the pilot stays lit.
4.
If pilot goes out, repeat steps 1 – 3.
5.
Turn “ON” gas valve(s) to light main burners.
6.
For complete shut down, shut off gas valve.