background image

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

1

Owner’s Manual

     ARSM,  ARSB,  ARCM,  AROB,  AVB

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with 

the functions of the equipment and experienced with state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar 

with the functions of the equipment.
Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range equipment.

The gas pressure regulator provided with the equipment must be installed when the appliance is connected to the gas supply. 
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquids, brooms, rags, etc. 
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air and adequate clearance for 

air openings into the combustion chamber, for proper combustion and ventilation.  For proper operation of the appliance, do not 

obstruct the flow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988 

(or latest addenda).
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of 

that system in excess of 1/2 PSI.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure 

testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least 3/4" NPT.

ShIPPING DAMAGE CLAIM PROCEDURE
 
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory.  The transportation company 
assumes full responsibility for the safe delivery upon acceptance of the equipment. 

If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer.  Do not 
install or attempt to operate a damaged appliance.

1.  Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making 
     the delivery.
2.  File claim for damages immediately regardless of the extent of damages.
3.  For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and file  
  a "Concealed Damage" claim with them.  This should be done within fifteen (15) days from the date that delivery  
  is made to you.  Retain the shipping container for inspection.

IMPORTANT

INSTALLATION INSTRUCTIONS

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of California to 

cause cancer or reproductive harm.  California law requires businesses to warn customers of potential exposure to such substances.  

To minimize exposure to these substances, always operate this unit according to the Owners Manual, ensuring you provide proper 

ventilation when cooking with gas.

Summary of Contents for ARCM

Page 1: ...9898 toll free www americanrange com OWNER S MANUAL FOR PROFESSIONAL SERIES COUNTERTOP INFRARED BROILERS MODEL NUMBERS ARSM ARSB ARCM AROB AVB PROFESSIONAL QUALITY COOKING EQUIPMENT DESIGN CLASS FUNCT...

Page 2: ..._____________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date __________ Gas Ty...

Page 3: ...to maintain that just like brand new appearance and performance over years of day to day use If you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for...

Page 4: ...tion 1 Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Operating 3 4 Check for Gas Leaks 3 Open Burne...

Page 5: ...ping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any...

Page 6: ...tor is adjusted at the factory for 5 W C water column manifold gas pressure natural gas or 10 W C manifold gas pressure for propane gas operation Before connecting the regulator check the incoming lin...

Page 7: ...hen light standing pilot and adjust flame 1 4 high 6 Turn ON gas valve thermostat to light main burners 7 For complete shut down shut off gas valves and turn pilot adjustment screw clockwise to shut o...

Page 8: ...arly with hot soapy water during the day and a Stainless Steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material then use a wood or nylon scra...

Page 9: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5...

Page 10: ...ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 ARSM 1 O N OFF 26 27 28 18 24 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21...

Page 11: ...ries 10 A28021 Sleeve Ball 3 16 Tube Barrel Oversize 11 A28020 Nut Reducer 1 4 3 16 CC 10428 13 A32001 Knob Gas On Off Glossy Black Flat Down 14 A80109 Valve Gas Manual On Off Ul 10419 AR ARKB ARRB AE...

Page 12: ...anual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 8 ARSB 1 O F F O N O F F O N 2 3 4 5 7 8 9 10 13 11 14 19 21 12 16 17 18 2...

Page 13: ...andle ARSM 36 Heavy Duty 049W 1 1 4 x CTL 180 Grit 9 A32016 Knob Ball 1 3 4 3 8 Insert 10490 New Style 10 A43017 Bearing Ball 3 4 ID x 1 5 8 OD 10507 High Heat 12 A38000 Name Plate American Range 8 10...

Page 14: ...s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 ARCM 1 O N OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22...

Page 15: ...at Gas 018 ARSM ARCM 10489 L Style 9 A11118 Orifice Bell 018 AR AF Nat Gas 11001 A11110 Orifice Bell 0 010 LPG Gas 11002 10 A28021 Sleeve Ball 3 16 Tube Barrel Oversize 11 A28020 Nut Reducer 1 4 3 16C...

Page 16: ...Owner s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 AROB 1 2 3 4 6 7 8 9 10 11 12 14 15 16 17 18 19 20 13 21 5...

Page 17: ...10 A80109 Valve Gas Manual On Off UL 10419 AR ARKB ARRB AECB 11 A29003 Orifice Hood 53 1 2 Brass Flat Head MSD LP Gas AROB A29012 Orifice Hood 43 1 2 Brass 11043 AROB 13 A29231 Pilot Tip Left Assembl...

Page 18: ...s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 14 AVB 1 OFF O N 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Page 19: ...A44003 Nut Speed 6 Push Black 10601 9 A10014 Switch Toggle On Off 115V 10417 10 A28028 Adapter 3 8C x 3 8 27 Uns Brass 11 A29300 Valve Pilot Elbow Adjustable 10418 1 8 NPT 3 16 CC 12 A80109 Valve Gas...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: