background image

For installation on a non-combustible counter/floor only.

Owner’s Manual

      ARSM,  ARSB,  ARCM,  AROB,  AVB

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

3

CLEARANCES

          MODEL                                             NON-COMBUSTIBLE WALLS

COMBUSTIBLE WALLS

Rear

Sides

Rear 

Sides

ARSM 

0"

0"

4"

4"

ARSB

0"

0"

4"

4"

ARCM

0"

0"

4"

4"

AROB

0"

0"

4"

4"

AVB

0"

0"

4"

4"

Before lighting, check all joints in the gas supply line for leaks.  do not use An open flAme to check for leAks!  
Use soap and water solution.

GAS LEAKS - ChECK OPERATION

1.  Turn pilot valves to OFF position by turning adjustment screws clockwise.

2.  Turn ON the manual gas valve at the inlet side of the gas supply line.

3.  Check for gas leaks at the flexible coupling or gas connector fitting using a solution of one part soap and three parts water.

4.  Sparingly spray or brush the soapy solution at the gas fittings; active bubbling indicates location of gas leak.

5.  Turn pilot adjustment screw counter-clockwise, then light standing pilot and  

  adjust flame 1/4" high.

6.  Turn ON gas valve/thermostat to light main burners.

7.  For complete shut-down, shut off gas valves and turn pilot adjustment screw 

  clockwise to shut-off gas to the pilots.

PILOT ADJUSTMENT SCREW

MORE GAS

LESS GAS

+

-

RATING PLATE

 - 

The information on the rating plate defines the model, serial 

number, gas type (natural or liquid propane), operating pressures and burner BTU 

ratings.  It is essential for proper identification of the unit when requesting additional 

information or factory support.

rating plate

Appliances must be connected only to the type of gas specified on the rating plate.

WARNING

!

If a gas leak is detected turn off the manual gas valve at the inlet side of the gas line.  

Call your certified and licensed service technician.

Intertek

3013256

Intertek

MODEL:

SERIAL NO.

ARSM-36

GAS TYPE: NAT

MAN. PRESS:

IN. W.C.

5.0

INPUT-BTU/HOUR/BURNER

CLEARANCES

NON-COMB. COMB.

@ 20,000

BACK

SIDES

0”

0”

4”

4”

FOR USE ONLY ON NONCOMBUSTIBLE FLOORS

CURB MOUNT MUST HAVE 2” OVERHANG

INTENDED FOR OTHER THAN HOUSEHOLD USE.

ANSI Z83.11a/CSA 1.8a-2007 Food Service Equipment

XXXXXX-XXX

@

1

35,000

OPERATING INSTRUCTIONS

Summary of Contents for ARCM

Page 1: ...9898 toll free www americanrange com OWNER S MANUAL FOR PROFESSIONAL SERIES COUNTERTOP INFRARED BROILERS MODEL NUMBERS ARSM ARSB ARCM AROB AVB PROFESSIONAL QUALITY COOKING EQUIPMENT DESIGN CLASS FUNCT...

Page 2: ..._____________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date __________ Gas Ty...

Page 3: ...to maintain that just like brand new appearance and performance over years of day to day use If you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for...

Page 4: ...tion 1 Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Operating 3 4 Check for Gas Leaks 3 Open Burne...

Page 5: ...ping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any...

Page 6: ...tor is adjusted at the factory for 5 W C water column manifold gas pressure natural gas or 10 W C manifold gas pressure for propane gas operation Before connecting the regulator check the incoming lin...

Page 7: ...hen light standing pilot and adjust flame 1 4 high 6 Turn ON gas valve thermostat to light main burners 7 For complete shut down shut off gas valves and turn pilot adjustment screw clockwise to shut o...

Page 8: ...arly with hot soapy water during the day and a Stainless Steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material then use a wood or nylon scra...

Page 9: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5...

Page 10: ...ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 ARSM 1 O N OFF 26 27 28 18 24 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21...

Page 11: ...ries 10 A28021 Sleeve Ball 3 16 Tube Barrel Oversize 11 A28020 Nut Reducer 1 4 3 16 CC 10428 13 A32001 Knob Gas On Off Glossy Black Flat Down 14 A80109 Valve Gas Manual On Off Ul 10419 AR ARKB ARRB AE...

Page 12: ...anual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 8 ARSB 1 O F F O N O F F O N 2 3 4 5 7 8 9 10 13 11 14 19 21 12 16 17 18 2...

Page 13: ...andle ARSM 36 Heavy Duty 049W 1 1 4 x CTL 180 Grit 9 A32016 Knob Ball 1 3 4 3 8 Insert 10490 New Style 10 A43017 Bearing Ball 3 4 ID x 1 5 8 OD 10507 High Heat 12 A38000 Name Plate American Range 8 10...

Page 14: ...s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 ARCM 1 O N OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22...

Page 15: ...at Gas 018 ARSM ARCM 10489 L Style 9 A11118 Orifice Bell 018 AR AF Nat Gas 11001 A11110 Orifice Bell 0 010 LPG Gas 11002 10 A28021 Sleeve Ball 3 16 Tube Barrel Oversize 11 A28020 Nut Reducer 1 4 3 16C...

Page 16: ...Owner s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 AROB 1 2 3 4 6 7 8 9 10 11 12 14 15 16 17 18 19 20 13 21 5...

Page 17: ...10 A80109 Valve Gas Manual On Off UL 10419 AR ARKB ARRB AECB 11 A29003 Orifice Hood 53 1 2 Brass Flat Head MSD LP Gas AROB A29012 Orifice Hood 43 1 2 Brass 11043 AROB 13 A29231 Pilot Tip Left Assembl...

Page 18: ...s Manual ARSM ARSB ARCM AROB AVB 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 14 AVB 1 OFF O N 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Page 19: ...A44003 Nut Speed 6 Push Black 10601 9 A10014 Switch Toggle On Off 115V 10417 10 A28028 Adapter 3 8C x 3 8 27 Uns Brass 11 A29300 Valve Pilot Elbow Adjustable 10418 1 8 NPT 3 16 CC 12 A80109 Valve Gas...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: