CASTER INSTALLATION

When installing provided casters, match holes on the caster with holes on the oven bottom base and fasten with the 

hardware provided.  Locking-type casters must be installed in the front.

Ovens with casters

 

must be installed with the locking front casters supplied, a flexible connector complying with ANSI Z21.69.

CGA6.16 and a quick-disconnect device complying with ANSI Z21.41CGA 6.9.  Adequate means must be provided to limit the 

movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the 

appliance movement.

LEVELING 

A carpenter’s spirit level should be placed on the oven floor, and the unit leveled both front-to-back and side-to-side.  If the unit is 

not level, cakes, casseroles and any other liquid or semi-liquid batter will not bake evenly, burner combustion may become erratic, and 

the unit will not function properly.

If the kitchen floor is relatively smooth and level, the unit may be leveled by turning the "foot" section of the leg, since casters are not 

adjustable.  Identify the high corner and level the unit if the adjustment required exceeds the 1-1/4" limit use metal shims.

All American Range Corporation appliances are adjusted and tested before leaving the factory, effectively matching them to 

appropriate atmospheric conditions.  We recommend that adjustments and calibrations are performed upon installation to assure 

proper operation of the unit and avoid possible problems caused by rough handling or vibration during shipment.  This work must be 

performed only by qualified service personnel.  These adjustments are the responsibility of the customer and/or dealer and are not 

covered by warranty.

Check all gas connections for leaks with a soapy water solution before lighting the oven.  

DO NOT USE AN OPEN FLAME TO 

CHECK FOR LEAKS!  

Putting an open flame beside a new gas connection is extremely dangerous and may result in serious injury 

or death.

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

5

Owner’s Manual

         AR Series Ranges

When lighting the gas oven, dO NOT stand with your face close 
to the combustion chamber.

CAUTION

!

Summary of Contents for AR SERIES

Page 1: ...ANGES AR SERIES AR C SERIES AR NV SERIES PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 20...

Page 2: ..._______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date _______...

Page 3: ...ormation about how to install and set up the unit basic operating instructions and how to maintain that just like brand new appearance and performance over years of day to day use If you should encoun...

Page 4: ...ds and Codes 2 Gas Connection 3 Manual Shut OffValve 3 Rating Plate 3 Electric Standard Codes 4 Casters 5 Leveling 5 Typical Model Parts Identification 6 Installation Checklist 7 Operating 8 9 Check f...

Page 5: ...tation company assumes full responsibility for the safe delivery upon acceptance of the equipment If you receive a damaged product immediately contact your delivery company your dealer your builder or...

Page 6: ...iance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B14...

Page 7: ...C Adapter must be 3 4 male pipe thread D Flexible connector E Manual gas shut off valve F 3 4 gas supply G Use pipe joint compound A Gas pressure regulator B 90 Street elbow C Adapter must be 3 4 male...

Page 8: ...CS A39074 Installation Electric Utility Connections Standards and Codes Qualified installation personnel are individuals a firm or a company which either in person or through a representative are enga...

Page 9: ...d by turning the foot section of the leg since casters are not adjustable Identify the high corner and level the unit if the adjustment required exceeds the 1 1 4 limit use metal shims All American Ra...

Page 10: ...l AR Series Ranges TYPICAL MODEL PARTS IDENTIFICATION OVEN THERMOSTAT RIGHT FRONT RIGHT REAR REAR CENTER FRONT CENTER LEFT FRONT LEFT REAR BURNER ON LIGHT FAN SWITCH IF SO EQUIPPED CONVECTION INNOVECT...

Page 11: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 12: ...rotating forward to expose the safety valve 4 Push in and hold the safety valve button at the bottom of the oven 5 Light the pilot by repeatedly pressing the piezo electric ignition button keep safet...

Page 13: ...WALLS Rear Sides Rear Sides 0 0 4 12 For installation on a non combustible floor only To Shut Down the Gas Fired Convection Oven 1 Set the thermostat to the OFF position 2 Press the power switch to th...

Page 14: ...d clean the underside Oven Daily 1 Wipe clean the inside of the oven 2 Remove oven racks and clean with soap and water 3 Reassemble after cleaning 4 Remove racks and rack guides convection oven and cl...

Page 15: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 16: ...60 24 25 18 23 41 22 42 43 4 2 3 7 5 48 49 51 56 55 54 52 46 44 47 53 31 13 14 15 10 8 9 11 20 21 1 6 19 12A 34 12B 50 57 61 Owner s Manual AR Series Ranges 13592 Desmond St Pacoima CA 91331 818 897...

Page 17: ...te Mount No Brake NSF AR AGBU ACB 34 A35015 Caster 4 Swivel Plate Mount w Brake NSF AR AGBU ACB 37 A80100 Valve Safety TS 11J AR Ranges 10425 38 A24001 Elbow Orifice Mixr 1 4Px3 8 27 10010 39 A10010 I...

Page 18: ...897 0808 tel 888 753 9898 toll free www americanrange com 13 3 8 6 2 39 45 36 35 34 33 30 32 28 24 25 27 5 0 20 25 10 15 30 26 29 4 5 40 45 50 55 35 9 10 11 12 13 14 49 50 51 52 54 53 44 43 42 44 41...

Page 19: ...RC SAG 20 A32012 Bezel BJ Thermostat 21 A10011 Light Indicator 120V Red 12 7 10407 W Wire Lead Male Term 22 A10002 Switch Rocker ON OFF Innovection Oven 23 A28020 Nut Reducer 1 4 3 16CC 10428 24 A2802...

Page 20: ...preheats to 350 F in about ten minutes Thermostat may be defective Unit will require service Too little gas pressure dirty gas line Call for authorized service SYMPTOM Convection fan does not operate...

Page 21: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 22: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 24: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: