background image

INSTAllATIoN, oPERATIoN AND SERvICE PERSoNNEl

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are experienced 

in state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and understand 

and are familiar with the functions of the equipment.

Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range products.

VENTILATION HOODS

Means must be provided for any commercial, heavy-duty cooking appliance to exhaust combustion waste products to the outside 

of the building.  Usual practice is to place the unit under an exhaust hood.  Filters and drip troughs should be part of any industrial 

hood.  Consult local codes before constructing and installing a hood.

Room air movement should be monitored during installation.  Strong exhaust fans in the hood or in the overall air conditioning 

system can produce a slight vacuum in the room and/or cause air drafts – either may interfere with the pilot or main burner 

performance and can also be hard to diagnose.  If pilot burner or main burner outage problems persist – make up air openings or 

baffles may have to be provided in the room.

INSTALLATION - GAS STANDARDS AND CODES

IMPORTANT - 

The installation of this appliance must conform to local codes or, in the absence of local codes, with the National Fuel 

Gas Code ANSI Z223.1 Natural Gas Installation Code, CAN/CGA-B149-1 or the Propane Installation Code, CAN/CGA-B149-2 

as applicable, including:

1.  The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any 

  pressure testing of that system at test pressure in excess of 1/2 psi (3.45 kPa). 

2.  The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off 

     valve during any pressure testing of the gas supply piping system.

The appliance, when installed, must be wired and electrically grounded in accordance with local codes, or in the absence of local 

codes, with the National Electric Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2 as applicable.

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

2

1.  A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the appliance and gas pressure 
  regulator in the gas stream for safety and ease of future maintenance/service.
2.  The gas pressure regulator supplied with the appliance must be installed prior to connecting the equipment to the gas 
  supply line.  Failure to install a regulator will void the equipment warranty and result in a potentially hazardous condition.
3.  Please contact the factory, a factory representative, or local service company to perform maintenance and repairs.

DANGER

!

Owner’s Manual

         AR Series Ranges

INSTALLATION

Summary of Contents for AR SERIES

Page 1: ...ANGES AR SERIES AR C SERIES AR NV SERIES PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 20...

Page 2: ..._______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date _______...

Page 3: ...ormation about how to install and set up the unit basic operating instructions and how to maintain that just like brand new appearance and performance over years of day to day use If you should encoun...

Page 4: ...ds and Codes 2 Gas Connection 3 Manual Shut OffValve 3 Rating Plate 3 Electric Standard Codes 4 Casters 5 Leveling 5 Typical Model Parts Identification 6 Installation Checklist 7 Operating 8 9 Check f...

Page 5: ...tation company assumes full responsibility for the safe delivery upon acceptance of the equipment If you receive a damaged product immediately contact your delivery company your dealer your builder or...

Page 6: ...iance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code CAN CGA B14...

Page 7: ...C Adapter must be 3 4 male pipe thread D Flexible connector E Manual gas shut off valve F 3 4 gas supply G Use pipe joint compound A Gas pressure regulator B 90 Street elbow C Adapter must be 3 4 male...

Page 8: ...CS A39074 Installation Electric Utility Connections Standards and Codes Qualified installation personnel are individuals a firm or a company which either in person or through a representative are enga...

Page 9: ...d by turning the foot section of the leg since casters are not adjustable Identify the high corner and level the unit if the adjustment required exceeds the 1 1 4 limit use metal shims All American Ra...

Page 10: ...l AR Series Ranges TYPICAL MODEL PARTS IDENTIFICATION OVEN THERMOSTAT RIGHT FRONT RIGHT REAR REAR CENTER FRONT CENTER LEFT FRONT LEFT REAR BURNER ON LIGHT FAN SWITCH IF SO EQUIPPED CONVECTION INNOVECT...

Page 11: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 12: ...rotating forward to expose the safety valve 4 Push in and hold the safety valve button at the bottom of the oven 5 Light the pilot by repeatedly pressing the piezo electric ignition button keep safet...

Page 13: ...WALLS Rear Sides Rear Sides 0 0 4 12 For installation on a non combustible floor only To Shut Down the Gas Fired Convection Oven 1 Set the thermostat to the OFF position 2 Press the power switch to th...

Page 14: ...d clean the underside Oven Daily 1 Wipe clean the inside of the oven 2 Remove oven racks and clean with soap and water 3 Reassemble after cleaning 4 Remove racks and rack guides convection oven and cl...

Page 15: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 16: ...60 24 25 18 23 41 22 42 43 4 2 3 7 5 48 49 51 56 55 54 52 46 44 47 53 31 13 14 15 10 8 9 11 20 21 1 6 19 12A 34 12B 50 57 61 Owner s Manual AR Series Ranges 13592 Desmond St Pacoima CA 91331 818 897...

Page 17: ...te Mount No Brake NSF AR AGBU ACB 34 A35015 Caster 4 Swivel Plate Mount w Brake NSF AR AGBU ACB 37 A80100 Valve Safety TS 11J AR Ranges 10425 38 A24001 Elbow Orifice Mixr 1 4Px3 8 27 10010 39 A10010 I...

Page 18: ...897 0808 tel 888 753 9898 toll free www americanrange com 13 3 8 6 2 39 45 36 35 34 33 30 32 28 24 25 27 5 0 20 25 10 15 30 26 29 4 5 40 45 50 55 35 9 10 11 12 13 14 49 50 51 52 54 53 44 43 42 44 41...

Page 19: ...RC SAG 20 A32012 Bezel BJ Thermostat 21 A10011 Light Indicator 120V Red 12 7 10407 W Wire Lead Male Term 22 A10002 Switch Rocker ON OFF Innovection Oven 23 A28020 Nut Reducer 1 4 3 16CC 10428 24 A2802...

Page 20: ...preheats to 350 F in about ten minutes Thermostat may be defective Unit will require service Too little gas pressure dirty gas line Call for authorized service SYMPTOM Convection fan does not operate...

Page 21: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 22: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 24: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: