Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with 

the functions of the equipment and experienced with state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar 

with the functions of the equipment.
Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range equipment.

The gas pressure regulator provided with the equipment must be installed when the appliance is connected to the gas supply. 
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquids, brooms, rags, etc. 
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air and adequate clearance for 

air openings into the combustion chamber, for proper combustion and ventilation.  For proper operation of the appliance, do not 

obstruct the flow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988 

(or latest addenda).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of 

that system in excess of 1/2 PSI.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure 

testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least 3/4” NPT.

SHIPPING DAMAGE CLAIM PROCEDURE
 
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory.  The transportation company 
assumes full responsibility for the safe delivery upon acceptance of the equipment. 

If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer.  Do not 
install or attempt to operate a damaged appliance.

1.  Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making 
     the delivery.
2.  File claim for damages immediately regardless of the extent of damages.
3.  For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and file  
  a "Concealed Damage" claim with them.  This should be done within fifteen (15) days from the date that delivery  
  is made to you.  Retain the shipping container for inspection.

IMPORTANT

INSTALLATION INSTRUCTIONS

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of California to 

cause cancer or reproductive harm.  California law requires businesses to warn customers of potential exposure to such substances.  

To minimize exposure to these substances, always operate this unit according to the Owners Manual, ensuring you provide proper 

ventilation when cooking with gas.

Summary of Contents for AMBG-36

Page 1: ...N BARBEQUE GRILL MODEL NUMBERS AMBG 36 AMBG 42 AMBG 48 AMBG 50 AMBG 60 PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrang...

Page 2: ...__________________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ____...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...y Information 1 Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Clearances 3 OPERATING 3 4 Check for...

Page 5: ...iping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any...

Page 6: ...gas flow direction arrow is cast into the body of the regulator to minimize installation error it should point downstream to the appliance The blue air vent cap on the top of the regulator is part of...

Page 7: ...e inlet side of the gas supply line 3 Check for gas leaks at the flexible coupling or gas connector fitting using a solution of one part soap and three parts water 4 Sparingly spray or brush the soapy...

Page 8: ...up allow 1 2 to 1 minute for air trapped in the gas lines to bleed while holding the safety control ignition button A qualified gas service technician can bleed the line from the pressure test port It...

Page 9: ...he size of the top up to four chefs can cook simultaneously as they saut vegetables fish meat and polurty as guests watch The Mongolian Barbeque Grills are similar to a tepanyaki griddle but much more...

Page 10: ...ot Burner not burning high Set valve to desired setting SYMPTOM Grill not getting hot enough Unit may not have been operating long enough Unit preheats to 350 F in about ten minutes on high setting Sa...

Page 11: ...A80106 Valve Gas Ball 1 2 x 1 2 AESP 10492 11 A80102 Valve Gas AF Series NAT Gas 11114 A80103 Valve Gas AF Series LPG Gas 11114 12 A11103 Pilot AF 6CH14 6N 018 Nat Gas 11105 A11121 Pilot AF 6CH14 6 0...

Page 12: ...licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified installation mus...