background image

INSTALLTION INSTRUCTIONS  

LIGHTING AND OPERATION OF H-BURNER 

FILLING H-BURNER WITH GLASS 

Step 3 

 
1.) Begin by completely covering 

BURNER TUBES 

(See figure 4)

 with glass first.  

 
2.) Focus first on covering the entire 

BURNER TUBES 

before spreading evenly within the firebox floor. 
 
3.) Use the entire bag of glass that is provided with the 
burner.  
 
4.) Spread the remaining glass evenly on the firebox 
floor without exposing 

BURNER TUBES

WARNING: DO NOT FLAME TEST FOR LEAKS

 

MANUAL MATCH LIGHTING 

 

 Standard Match Lit       (H

-BURNER FOR      NATU-
RAL GAS ONLY) 
 

1. Place lighted match 

(See Figure 4) 

on glass near inlet end of burner. 

DO 

NOT HOLD MATCH IN HAND! 

Move 

away from front of fireplace. 
 
2. Slowly open 

FIREPLACE GAS 

SUPPLY VALVE 

and wait for burner 

to light.  
 
3. Adjust 

FIREPLACE GAS SUPPLY 

VALVE 

for desired flame height. 

 

WARNING: DO NOT ALLOW FLAMES FROM H-BURNER EXCEED THE HEIGHT OF 
THE  FIREPLACE OPENING. 
 

4. 

SHUTDOWN: 

Close 

FIREPLACE GAS SUPPLY VALVE 

completely. 

 

WARNING:DO NOT LEAVE BURNER UNATTENDED, WHILE H-BURNER IS BURNING. 

 

 

 

IMPORTANT: CHIMNEY DAMPER MUST BE WIDE OPEN

 

6. 

Figure 4 

Summary of Contents for SS-H-12

Page 1: ...flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in yo...

Page 2: ...insert or any other accessory not approved for use with this heater A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided the...

Page 3: ...an to inspect the appliance and to replace any part of the control system and any gas control which has been under water Important Use with other manufacture parts controls remotes parts and accessori...

Page 4: ...r Clamp Damper Blade Opening Height Minimum See Page 5 FIGURE 1 Gas Supply Valve Location may vary per installation Gas Valve Key Burner Pan Positioning In Fireplace side view 1 Place BURNER inside fi...

Page 5: ...ections for leaks with soapy water solution If solution bubbles turn off gas supply retighten fitting and recheck If leaks are found turn off gas immediately and leave 5 Rear Width Not less than H Bur...

Page 6: ...ING DO NOT FLAME TEST FOR LEAKS MANUAL MATCH LIGHTING Standard Match Lit H BURNER FOR NATU RAL GAS ONLY 1 Place lighted match See Figure 4 on glass near inlet end of burner DO NOT HOLD MATCH IN HAND M...

Page 7: ...clockwise to raise up to full on FULL ON IMPORTANT INFORMATION ON YOUR VALVE GAS CONTROL It is intended to prevent premature valve failure and voiding of warranty Replace immediately if removed for an...

Page 8: ...RECEIVER HAS 3 POSITIONS OFF FULL ON AND REMOTE ACCESS ON Note Consult Operating Instructions for Accessory Control KNOB OPERATION 8 1 See above instructions on Pilot Lighting Instructions 2 Turn VAL...

Page 9: ...n PILOT ADJUSTMENT SCREW 3 Turn clockwise for less flame counterclockwise for more 4 If after pilot adjustment the burner begins to shutdown re adjust for a longer pilot flame WARNING CHIMNEY DAMPER M...

Page 10: ...red to act as a heat deflector in protecting combustible fireplace surrounds facing and or mantel if certain minimum clearance cannot be met Be certain that combustible flooring material i e carpet ti...

Reviews: