VM32/AD32
Supported Protocols
SensorNet
RS-422
(1)
Maximum Presets
96 – SensorNet
4 – RS-422
Maximum Patterns
(2)
3
Quick Set Menu
Not supported
Address Range
1-32
Notes:
(1) Requires RCSN422 code converter.
(2) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.
VM96
(1)
Supported Protocols
SensorNet
RS-422
Maximum Presets
Unlimited
(2)
Maximum Patterns
(3)
3
Quick Set Menu
Not supported
Address Range
1-96
Notes:
(1) Requires software version 5.2 or newer.
(2) Preset information is stored at the host, not the
dome.
(3) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.
AD2150/AD2350
Supported Protocol
RS-422
(1)
Maximum Presets
16
(2)
or 60
(3)
Maximum Patterns
(4)
3
Quick Set Menu
Not supported
Address Range
1-32
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not
the dome.
(3) Requires AD2083-02 with firmware version 0701-
11YB-156A or newer. Preset information is stored
in the dome, not the converter.
(4) Patterns are limited by time and the number of
available dome commands. Total time for each
pattern cannot exceed 6 minutes 50 seconds.
Total dome commands used in all patterns cannot
exceed 99.
AD1650
Supported Protocol
RS-422
(1)
Maximum Presets
16
(2)
or 60
(3)
Maximum Patterns
(4)
3
Quick Set Menu
Not supported
Address Range
1-128
(5)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-11YB-
156A or newer. Preset information is stored in the
dome, not the converter.
(4) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.
A-4
SpeedDome Ultra VII Day/Night Operator's Manual
Summary of Contents for SpeedDome Ultra VII RAS917LS
Page 2: ......
Page 10: ...N O T E S viii SpeedDome Ultra VII Day Night Operator s Manual ...
Page 26: ...N O T E S 2 8 SpeedDome Ultra VII Day Night Operator s Manual ...
Page 68: ...N O T E S 5 12 SpeedDome Ultra VII Day Night Operator s Manual ...
Page 76: ...N O T E S SpeedDome Ultra VII Day Night Operator s Manual 7 4 ...
Page 98: ...N O T E S D 6 SpeedDome Ultra VII Day Night Operator s Manual ...
Page 104: ...E 6 SpeedDome Ultra VII Day Night Operator s Manual ...
Page 122: ...N O T E S S 4 SpeedDome Ultra VII Day Night Operator s Manual ...
Page 129: ......