background image

RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 

8000-2573-20, REV. H 

INSTALLATION GUIDE 

6 of 10

 

6.  Run conduit and ac cable to box and clamp 

conduit in place (Figure 7). 

7.  Reattach transformer chassis. 

Figure 7. Conduit attachment 

 

8.  Wire ac line to TB1 and jumper primary taps of 

transformer according to ac source (refer back 
to Figure 6). 

120Vac:

 Place a jumper across taps 1 and 3, 

and another jumper across taps 2 and 4. 

240Vac: Place a jumper across taps 2 and 3 
only. 

9.  Reattach PC board assembly. 

Changing the Fuse 

To reduce the risk of fire, replace fuses with the 
same type and rating (3:15A type IEC127, sheet 
III). The part number for the fuse is 5111-0017-21. 
Two spare fuses are provided inside the cover.  

To access fuse, use a small slotted screwdriver to 
unscrew the cap of the fuse holder (Figure 7) and 
lift out the fuse. 

 

Connecting Power and  
Data Cables 

Note:

 Incoming and outgoing video cables are 

connected together within the box. No termination 
exists for video cables within the J-box. 

Power Cable Requirements 

The low-voltage power cable runs between the J-
box and the camera dome. The length of this 
cable depends on the ac line voltage. See Table 1 
for cable lengths based on worst case low line 
voltages for Japan (100Vac), North America 
(120vac), and Europe (240vac). 

Table 1. Cable length vs. line voltage 

Worst Case 

Line 

Voltages

 

18AWG 16AWG  14AWG 

90 Vac 

(Japan) 

30m (100ft)  50m (160ft) 

80m (260ft)

102 Vac  

(N. Amer.) 

60m (200ft)  100m (320ft) 160m (520ft)

180 Vac 

(Europe) 

30m (100ft)  50m (160ft) 

80m (260ft)

204 Vac 

(Europe) 

60m (200ft)  100m (320ft) 160m (520ft)

Data Cable Requirements 

Wires within the data cable are organized in two 
polarized 22AWG, shielded, twisted pairs. Up to 
1km (3000ft) of data cable can be run from the 
Host to the J-box, or from J-box to J-box (see 
CAUTION below). For more information about the 
RS-422 communication protocol and possible 
cable network configurations, see 

Communication 

Protocols and Cable Networks

, 8000-2573-19.  

CAUTION:

 Data cable from the J-box to the dome 

is limited by the length of the power cable. See 
Table 1 above. 

Note: 

Power, data, and video cables can be 

ordered separately or within a composite cable 
ordered in various lengths. Plenum-rated cables 
must be used in indoor ceilings used for 
environmental air return (called “other air space” in 
the National Electrical Code). Order parts through 
your distribution network. If you order cable from 
an outside source, wire colors may be different. 

Conduit 

Fuse holders 

Summary of Contents for RJ856UD Series

Page 1: ...fachen Zugang zum Ger t erlaubt Outside elements To keep outside elements from entering the J box always mount it vertically with cable exits facing down and tighten the four plastic screws Adding acc...

Page 2: ...ncrete wood sheet rock Dimensions H x W x D 200 x 200 x 132mm 7 87 x 7 87 x 5 19 in Mounting area H x W 281 x 200mm 11 x 8 in Weight 3 7 kg 8 25 lbs Construction Polycarbonate non metallic enclosure C...

Page 3: ...e 2 1 Using the upper and lower mounting brackets of the box as templates mark mounting hole locations The two center top slots in the upper bracket match the bolt spacing used for older J boxes CAUTI...

Page 4: ...shown in Figure 4c with J box on ground and its rear facing towards you a Slip one of the two bands through closed slots in lower mounting bracket Pick slots appropriate for the width of the pole b Be...

Page 5: ...ts CAUTION Keep the disconnect device circuit breaker readily accessible when hardwiring J box Do the following 1 Unplug line cord from ac outlet 2 Loosen two screws then slide and lift circuit board...

Page 6: ...ds on the ac line voltage See Table 1 for cable lengths based on worst case low line voltages for Japan 100Vac North America 120vac and Europe 240vac Table 1 Cable length vs line voltage Worst Case Li...

Page 7: ...N1 HI SHIELDS GND AUX OUT2 LO AUX OUT 2 HI AUX OUT1 LO AUX OUT1 HI 1 2 3 4 5 6 7 8 9 Testing for Data To test for data into J Box Press and hold switch S1 Figure 9 Good data is indicated by DS1 glowin...

Page 8: ...still no data see Removing the Circuit Board below Removing the Circuit Board Follow steps to remove the circuit board Reverse steps to reassemble 1 Loosen four captive screws to release cover 2 Remo...

Page 9: ...S 422 PC Board 0312 0163 02 Power Transformer 5604 0205 01 Cable Strain Relief 3100 0035 11 Fuse 5111 0017 21 These parts are shown bold in Figure 13 Figure 13 Exploded view of RS 422 J box Strain Rel...

Page 10: ...or FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or war...

Reviews: