RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 

8000-2573-20, REV. H 

INSTALLATION GUIDE 

2 of 10

 

RS-422 Single-Position  
J-Box Specifications 

REG ID: SV JBOX1 

Product Codes 

RJ856UD ..............................120V with North American 

line cord 

RJ856UD-1 ...........................230V with Continental 

European line cord 

Transformer primary jumpers and mains line cord are 
field changeable to support either 120Vac or 230Vac 

Electrical 

Power source ........................100–120Vac or 200–

240Vac. 50/60Hz 

Fuse......................................3.15A type IEC127, 

sheet III 

Max. operational limits ..........90–135Vac or 180–

265Vac, 50/60Hz 

Input current..........................1.0A/.5A 
Output ...................................26Vac, 2.4A max.  

Class 2 LPS 

Power line protection ............Gas Discharge tube 

impulse rated at 8/20µs 
impulse discharge current: 
10kA 

Operational 

Diagnostic LEDs ...................Push button controlled 

data in / data out 

Power....................................On/Off switch 
Compatible with ....................SpeedDome Ultra outdoor 

housing 

Mechanical 

Environment..........................Indoor / Outdoor 
Wall mounting options...........concrete, wood, sheet rock 
Dimensions (H x W x D)........200 x 200 x 132mm  

(7.87 x 7.87 x 5.19 in.) 

Mounting area (H x W)..........281 x 200mm  

(11 x 8 in.) 

Weight:..................................3.7 kg (8.25 lbs) 
Construction..........................Polycarbonate, non-

metallic enclosure 

Color .....................................Light gray 
Cover locks ...........................2 quick-release latches 
Cable access ........................3 ½-inch NPT strain relief 

fittings provided for power, 
host, and dome cables.  

RS-422 Communication Interface 

Cable distance: 

J-box to J-box ..................1km (3000ft) 
Host to J-box....................1km (3000ft) 
J-box to camera dome .....Limited by the length of the 

low-voltage ac power 
cable. See Table 1 on 
page 6. 

Cable type .............................2 shielded twisted pair, 

22AWG, polarized 

Surge protection....................TVS impulse rated at 

1500W, 100A, 10/1000µs 

Connectors: 

Host .................................Spring-loaded 
Aux ..................................Spring loaded 
Dome ...............................Euro-style terminal 

Environmental 

Weatherproof standard .........NEMA 4 / IP66 
Operating temperature ..........–40°C to 50°C  

(–40°F to 122°F) 

Storage temperature .............–10°C to 50°C  

(14°F to 122°F) 

Relative humidity...................0 to 95% non-condensing 

Regulatory 

EMC ......................................47 CFR, Part 15, Class A 

EN55022, Class B 

Immunity................................EN50082-1 
Safety....................................UL1950 

CSA 22.2, No. 950 
EN60950 

See additional declarations on last page. 

 

Summary of Contents for RJ856UD Series

Page 1: ...fachen Zugang zum Ger t erlaubt Outside elements To keep outside elements from entering the J box always mount it vertically with cable exits facing down and tighten the four plastic screws Adding acc...

Page 2: ...ncrete wood sheet rock Dimensions H x W x D 200 x 200 x 132mm 7 87 x 7 87 x 5 19 in Mounting area H x W 281 x 200mm 11 x 8 in Weight 3 7 kg 8 25 lbs Construction Polycarbonate non metallic enclosure C...

Page 3: ...e 2 1 Using the upper and lower mounting brackets of the box as templates mark mounting hole locations The two center top slots in the upper bracket match the bolt spacing used for older J boxes CAUTI...

Page 4: ...shown in Figure 4c with J box on ground and its rear facing towards you a Slip one of the two bands through closed slots in lower mounting bracket Pick slots appropriate for the width of the pole b Be...

Page 5: ...ts CAUTION Keep the disconnect device circuit breaker readily accessible when hardwiring J box Do the following 1 Unplug line cord from ac outlet 2 Loosen two screws then slide and lift circuit board...

Page 6: ...ds on the ac line voltage See Table 1 for cable lengths based on worst case low line voltages for Japan 100Vac North America 120vac and Europe 240vac Table 1 Cable length vs line voltage Worst Case Li...

Page 7: ...N1 HI SHIELDS GND AUX OUT2 LO AUX OUT 2 HI AUX OUT1 LO AUX OUT1 HI 1 2 3 4 5 6 7 8 9 Testing for Data To test for data into J Box Press and hold switch S1 Figure 9 Good data is indicated by DS1 glowin...

Page 8: ...still no data see Removing the Circuit Board below Removing the Circuit Board Follow steps to remove the circuit board Reverse steps to reassemble 1 Loosen four captive screws to release cover 2 Remo...

Page 9: ...S 422 PC Board 0312 0163 02 Power Transformer 5604 0205 01 Cable Strain Relief 3100 0035 11 Fuse 5111 0017 21 These parts are shown bold in Figure 13 Figure 13 Exploded view of RS 422 J box Strain Rel...

Page 10: ...or FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or war...

Reviews: