Troubleshooting 

Problem Possible 

Solution 

No Power 

First check both fuses, then look 
for open or loose wire connections 
at TB1. If loose, reconnect wires. 

Measure voltage across 0 and 24V 
taps of secondary winding on 
transformer. If open, replace 
transformer. See “Removing the 
Transformer” opposite. 

No Data 

Check for loose wires. If DS1 LED 
does not glow green, see “Testing 
for Data” on page 7. If still no data, 
see “Removing the Circuit Board” 
below. 

 

 

 

Removing the Circuit Board 

Follow steps to remove the circuit board. Reverse 
steps to reassemble. 

1.  Loosen four captive screws to release cover. 

2.  Remove six screws to remove circuit board 

(Figure 10). 

Figure 10. 

 

Removing the Transformer 

Follow steps to remove the transformer. Reverse 
steps to reassemble. 

1.  Loosen four captive screws to release cover. 

2.  As shown in Figure 10, loosen two screws and 

slide chassis in direction of arrows. Gently lay 
chassis on inside front cover while working on 
transformer. Slide PCB chassis out of box. 

Figure 11.  

 

 

3.  Remove four nuts to remove transformer 

(Figure 12). 

Figure 12.  

 

 

Screws (2) 

Screws (6) 

Nuts (4) 

Summary of Contents for RJ856UD Series

Page 1: ...fachen Zugang zum Ger t erlaubt Outside elements To keep outside elements from entering the J box always mount it vertically with cable exits facing down and tighten the four plastic screws Adding acc...

Page 2: ...ncrete wood sheet rock Dimensions H x W x D 200 x 200 x 132mm 7 87 x 7 87 x 5 19 in Mounting area H x W 281 x 200mm 11 x 8 in Weight 3 7 kg 8 25 lbs Construction Polycarbonate non metallic enclosure C...

Page 3: ...e 2 1 Using the upper and lower mounting brackets of the box as templates mark mounting hole locations The two center top slots in the upper bracket match the bolt spacing used for older J boxes CAUTI...

Page 4: ...shown in Figure 4c with J box on ground and its rear facing towards you a Slip one of the two bands through closed slots in lower mounting bracket Pick slots appropriate for the width of the pole b Be...

Page 5: ...ts CAUTION Keep the disconnect device circuit breaker readily accessible when hardwiring J box Do the following 1 Unplug line cord from ac outlet 2 Loosen two screws then slide and lift circuit board...

Page 6: ...ds on the ac line voltage See Table 1 for cable lengths based on worst case low line voltages for Japan 100Vac North America 120vac and Europe 240vac Table 1 Cable length vs line voltage Worst Case Li...

Page 7: ...N1 HI SHIELDS GND AUX OUT2 LO AUX OUT 2 HI AUX OUT1 LO AUX OUT1 HI 1 2 3 4 5 6 7 8 9 Testing for Data To test for data into J Box Press and hold switch S1 Figure 9 Good data is indicated by DS1 glowin...

Page 8: ...still no data see Removing the Circuit Board below Removing the Circuit Board Follow steps to remove the circuit board Reverse steps to reassemble 1 Loosen four captive screws to release cover 2 Remo...

Page 9: ...S 422 PC Board 0312 0163 02 Power Transformer 5604 0205 01 Cable Strain Relief 3100 0035 11 Fuse 5111 0017 21 These parts are shown bold in Figure 13 Figure 13 Exploded view of RS 422 J box Strain Rel...

Page 10: ...or FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or war...

Reviews: