background image

MEGAPOWER 3200 RELEASE 2.0 

8200-0421-19, REV. A 

RELEASE NOTES 

6 of 16

 

13.  Multi-dome control protocols directly from ADMPCPU 

 

Address range can be uniquely configured for each connection. 

 

The ADMPCPU has two RS-422/485 connections, each supporting 100 addresses. 

 

RS-422, Manchester, and SensorNet address ranges can be user defined for better system 
performance. 

 

The user can perform ping tests (dome communication test) on SensorNet and duplex RS-422 
domes. 

The domes will display for few seconds the dome’s programmed Flash part number (including 
firmware version) and mnemonic. The ping test data is then collected and displayed for the remainder 
of the test on the selected monitor. 

 

SensorNet and Manchester share the same data connectors on the rear panel of the MPCPU, 
thus only one protocol can be configured at a time.

 

The two data connection ports can be independently set for SensorNet or Manchester communication 
protocols. 

 

The two RS-422/485 connections can be configured as RS-232 line drivers. 

This allows the user to connect to the ADAC422D RS-422/RS-485 distribution panel when it is 
desirable to use an RS-232 connection. 

 

The added connections allow the user to use ADACSNETD SensorNet and ADAC422D  
RS-422/RS-485 Distribution Panels to provide more flexible wiring topologies, including home 
run, daisy chain, and J-Box connectivity for both small and large systems. 

The added connections also allow: 
-  Alarm contacts, tours, and salvos to call up to 96 presets (SensorNet or RS-422) and three patterns 

(13 with SpeedDome Ultra 8 & 7E, see Table 2). 

-  Direct connection to control older domes as well as new domes. Legacy fixed RS-422 speed domes 

are supported (including Mini-dome and UTPZ models) to the best practical performance level. 
Legacy domes are supported (see the “Legacy Dome Support” section). 

 

 

When SpeedDome Ultra VIIE or SpeedDome Ultra 8 is configured into the 16-pattern mode, the 
MPCPU has the following pattern run/program capability: 

From the keyboard (SensorNet or RS-422): 

Pattern 1-3: This selection causes a grid to be displayed from which pattern 1-16 can be selected (to 
run or program). Once selected from the grid, the pattern works properly. 
Pattern 4-16: Attempting to run or program pattern 4-16 will only cause a beep with nothing else 
happening. To access pattern 4-16, select pattern 1, then select pattern 4-16 from the grid. 

Programming patterns into Alarms, Tours, or Salvos for SensorNet domes: 

Pattern 1-3: Upon activation, displays a grid from which the operator must select desired pattern 
number, and then press Focus Far on keyboard. 
Pattern 4-16: This pattern works correctly. 

Programming patterns into Alarms, Tours, or Salvos for RS-422 domes: 

Pattern 1-3: Upon activation, displays a grid from which the operator must select desired pattern 
number, and then press Focus Far on keyboard. 
Pattern 4-16: These patterns are not available. 

 

Summary of Contents for MegaPower 3200 2.0

Page 1: ...ncements introduced in this release Document revisions for Release 2 0 Table 1 Available documents for Release 2 0 Description Number Revision Date MegaPower CPU Install and Service Guide 8200 0421 01...

Page 2: ...assive Hot Switch status 4 7 New Icons for Better Application Browsing 4 8 Enhanced menu read write and backup of configuration files 4 9 Configuration file properties 4 10 Chinese and Korean language...

Page 3: ...Monitor Camera and Error Log status can be selected with radio button for either MPCPU A or MPCPU B The radio button text at the top of screen contains the MPCPU A and B Status such as Selected Backup...

Page 4: ...The ADMPCPU default or configured IP address Write to both dual configured ADMPCPUs as specified by MPCPU A and MPCPU B IP Hostnames in the Systems Options menu Save the configuration file to a folde...

Page 5: ...with firmware version 2 0 315 This new firmware allows Korean and Chinese characters to display on the MP3200 matrix output monitor 11 Addition of tool tips for enhanced application browsing The user...

Page 6: ...Box connectivity for both small and large systems The added connections also allow Alarm contacts tours and salvos to call up to 96 presets SensorNet or RS 422 and three patterns 13 with SpeedDome Ult...

Page 7: ...64 60 3 N N 0 Y N Y AD2083 02C 1 99 60 3 N N 0 Y N Y AD2083 02B 1 99 1 16 3 N N 0 Y N Y SpeedDome Optima LT ADDL AD2091 1 64 60 3 N N 0 Y N Y SensorNet 1 254 96 3 Y 3 Y 1 Y Y Y RS 422 485 1 100 96 3 Y...

Page 8: ...programmable therefore they can not support presets patterns peel or flip features Legacy Dome Support To simplify support of various dome types and generations a simple connection setting will addre...

Page 9: ...6 with Version 3 xx FW Variable Fixed SpeedDome Ultra 1 II none Inaccurate fixed speed 7 Variable Fixed SpeedDome all none Inaccurate fixed speed 7 Variable Fixed Mini UTPZ and older none none 7 none...

Page 10: ...sion Number Viewer VW1 0037 0710 0156 0102 SpeedDome Optima LT SDOLT 0013 0710 0174 0102 SpeedDome Optima SDO 1 2233 0701 2843 0110 SpeedDome Ultra 8 SDU8 0150 0710 0882 0100 SpeedDome Ultra VIIE SDU7...

Page 11: ...he ADMPCPU The new features of Release 2 0 that require configuration cannot be enabled and users will need to upgrade to EASY CPU to obtain Release 2 0 features ADMPCPU V2 00 can read and store V1 00...

Page 12: ...s and enhancements Also new problems will require upgrade to the latest versions to isolate and resolve such issues EASY CPU Release 2 0 shall be compatible with Microsoft XP Professional Service Pack...

Page 13: ...n each error message that appears and then enter the correct IP address for the MPCPU in either the Systems Options CPU 1 screen or in the File Read dialog box 1873 The 1030 LCD error code displays on...

Page 14: ...cation 2085 Satellite host port can be same for multiple sites The user can delete the row on EASY CPU definitions satellite sites 2097 ADMPCPU not updating DBVL card after a factory reset Fixing will...

Page 15: ...d incorrectly sets record bits to EASY CPU 2018 EZ CPU Satellite Sites won t accept Host Port values of zero if already set to value greater than zero 2019 Switching Salvo Alarm Contacts screen Add Re...

Page 16: ...entered 2413 Possible to set a tours dwell time to more than 60 seconds 2415 Event timer alarms do not disable Limitations Sorting is disabled in the Camera Status screen to ensure that the live statu...