 DIP Switch Default Settings 

1.  Automatic White Balance (On) 
2. Gamma 

(On) 

3.  Automatic Gain Control (On) 
4. Electronic 

Sensitivity Control (Off) 

5.  Back Light Compensation (Off) 
6.  Flicker Less (On) 
7. AE 

(On) 

8.  Not Used (Don’t Care) 

 

8 7

6 5 4

3

2

1

OFF

 
 
 

AC/Heater Wiring Diagram 

(Corner Mount or  
Surface Mount only) 

 

J3

J1

J2

SW1

SW1 (Thermostat)

J2

J1

J3

Heater

AC to Camera

AC In

 

 

 

 

AC/Heater/Fan  
Wiring Diagram 

(Surface Mount only) 

Note:  

  Red wire from the fan goes to the J3 terminal 

marked “+”. 

  “AC In” and “AC to the Camera” both connect 

to the J1 terminal. 

SW1 (Thermostat)

24Vac

Reg.

12Vac

Reg.

Heater

AC In

AC to Camera

J2

J1

J3

+

Fan

J3

J1

J2

SW1

 

Summary of Contents for ADC780

Page 1: ...heater and thermostat that maintains the operating temperature between 40 C to 50 C 2005 Sensormatic Electronics Corp Features Adjustable camera mount Indoor Outdoor installation except flush mount and inch conduit holes 24Vac hookup 2 6 6mm variable focal color camera with dc auto iris adjustment Parts Supplied Caution Installation should be performed by qualified service personnel and in accorda...

Page 2: ...In extreme environments Wrap the screw head in Teflon tape with the tape going inch down the body of the screw A and insert the washer and O ring B Otherwise just use the washer and O ring B The O ring goes on last 3 Using the four mounting screws attach the enclosure to the corner Use Teflon tape to wrap the ends of the conduit before connecting it to the enclosure M6x35 Screws 4x Teflon Tape Rub...

Page 3: ... switch settings page 8 9 Holding the yoke not the camera lens barrel swivel the camera to the desired view Caution DO NOT point the camera directly at the sun s path 10 Adjust zoom and focus arms on the lens barrel to the desired setting and tighten them in place 11 Tighten the two yoke screws 12 If the humidity is high at the time of installation place the bag of desiccant inside the enclosure 1...

Page 4: ...own Apply power to the camera 4 Holding the yoke not the camera lens barrel swivel the camera to adjust using a small screwdriver the auto iris level control on the edge of the top board 5 Swivel the camera to adjust the ac phase control on the edge of the bottom board 6 Select DIP switch settings page 8 7 Holding the yoke not the camera lens barrel swivel the camera to the desired view Caution DO...

Page 5: ...to wrap the ends of the conduit before connecting it to the enclosure 4 If connecting to an electrical box see Electrical Box Attachment page 5 If using the camera outdoors see Heater Installation page 7 If humidity is a factor see Heater Fan installation page 7 5 Run 24vac and video cables to the enclosure Connect cables where shown and apply power to the camera 6 Holding the yoke not the camera ...

Page 6: ...on place the bag of desiccant inside the enclosure 13 Reattach the cover on the enclosure using the four Torx screws 14 Place a bead of Silicone caulk everywhere where the surface mount meets the wall Electrical Box Attachment Flush Mount 1 Attach the mounting plate to the electrical box using four 8 32 screws shown 2 Attach the enclosure to the mounting plate using four M4 x 8 screws Note Due to ...

Page 7: ...C camera connection and replace it with the thermo stat PC board and heater element Each compon ent is held in place by two screws For wiring details see ac heater wiring diagram on page 8 Heater Fan Installation Surface Mount only Remove the ac terminal block and wiring to the AC camera connection and replace it with the thermo stat PC board and the heater fan assembly Each component is held in p...

Page 8: ...tion Off 6 Flicker Less On 7 AE On 8 Not Used Don t Care 8 7 6 5 4 3 2 1 OFF AC Heater Wiring Diagram Corner Mount or Surface Mount only J3 J1 J2 SW1 SW1 Thermostat J2 J1 J3 Heater AC to Camera AC In AC Heater Fan Wiring Diagram Surface Mount only Note Red wire from the fan goes to the J3 terminal marked AC In and AC to the Camera both connect to the J1 terminal SW1 Thermostat 24Vac Reg 12Vac Reg ...

Page 9: ...P GUIDE 9 of 11 Dimensions Corner Mount PT 3 4 PT 1 2 124 2mm 4 9 75mm 2 95 120mm 4 73 104 6mm 4 12 86mm 3 39 100mm 3 94 Flush Mount 91 5mm 3 6 86 0mm 3 39 85 0mm 3 35 52 5mm 2 07 40 0mm 1 57 120 0mm 4 72 120 0mm 4 72 Surface Mount 91 5mm 3 60 86 0mm 3 39 120 0mm 4 72 120 0mm 4 72 ...

Page 10: ...non condensing Storage temp 20 C to 60 C 4 F to 140 F North America Listed Class 2 power supply required European Union Certified limited power source required Mechanical Dimensions see page 9 Weight Flush Mount 450g 1 lbs Surface Mount 590g 1 3 lbs Corner Mount 590g 1 3 lbs Color Light beige Operational Imager interline transfer CCD Video output 1 0Vp p 75 ohm composite Active pixel count NTSC 76...

Page 11: ...for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition Other Declarations WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Further Sensormatic Electronics...

Reviews: