24
American Dryer Corp.
113354 - 20
GAS AND STEAM
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
208
3ø
3
37
—
50
220
3ø
3
35
36
50
230
3ø
3
34
—
50
230
3ø
3
—
30
40
240
3ø
3
35
—
50
380
3ø
3
19
—
30
380
3ø
4
*
—
18
30
400 / 416
3ø
4
*
—
17
30
460 / 480
3ø
3
19
—
30
575
3ø
3
14
—
20
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label. In the
case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label
exactly
.
WARNING: 208 VAC AND 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
2. Electrical Service Specifications
8/20/14
* 3 Wire is available.
8/20/14
ELECTRIC
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT
:
NOTES
: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For
others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
220
3ø
3
106
312
—
400
240
3ø
3
126
338
—
425