1. Handling of Batteries

1.1 Do Not Short Circuit the Battery

Try to never short circuit the battery. It generates a very high 

current which could cause the battery to overheat which may 

result in electrolyte gel leakage, harmful fumes, or explosion. 

The LIR tabs may easily short-circuit by placing them on con-

ductive surface. A short circuit may lead to heat build up and 

damage of the battery. An appropriate circuitry with PCM is 

employed to protect accidental short circuit of the battery pack.
1.2 Mechanical shock

Droping the unit, impact hit, bending, etc. may cause failure or 

shortend life of the LIR battery.
3. Other

3.1 Battery connection

1). Direct soldering of wire leads or devices to the battery is 

strictly prohibited.
2). Lead tabs with pre-soldered wiring shall be spot welded to 

the batteries. Direct soldering may cause damage of compo-

nents, such as separator and insulator, by heat build up.
3.2 Prevention of short circuit within a battery pack

There is enough insulation layers between wiring and the bat-

teries to provide extra safety protection. The battery pack is 

constructed in a way that no short circuit will occur which may 

cause smoke or fire.
3.3 Do No Disassemble the Batteries

1). Never disassemble the batteries.

Doing this may cause a internal short circuit in the battery, 

which may lead to harmful fumes, fire, explosion, or other prob-

lems.
2). Electrolyte Gel is harmful

Electrolyte Gel should not leak from the LIR battery. Should the 

electrolyte gel come into contact with the skin or eyes, flush the 

area of contact immediately with fresh water and seek medical 

attention immediately.
3.4 Do Not Expose the Battery to Heat or Fire

Never incinerate or dispose of the batteries in fire. This may 

cause an explosion, which would be very dangerous.
3.5 Do Not Expose the Battery to water or liquids

Never soak/drop the batteries in liquids such as water, seawa-

ter, drinks such as soft drinks, juices, coffee or other.
3.6 Battery Replacement

For battery replacement please contact ADJ customer support 

(800) 322-6337.
3.7 Do Not use a damaged Battery

The battery could be damaged during shipping, caused by 

shock. Should the battery be found damaged, including dam-

ages to the plastic casing of the battery, deformation of the 

battery package, smelling of an electrolyte, or leakage of the 

electrolyte gel, or other, DO NOT use the battery. A battery with 

a odor of electrolyte or a gel leakage should be placed away 

from fire to avoid fire or explosion.
4. Battery Storage

When storing the battery, it should be stored at room tempera-

ture, with a charge of at least 50%. We recommend that during 

long periods of storage that the battery be charged every 6 

months. Doing this will prolong the life of the battery and will 

also make sure that the battery charge does not fall below the 

30% mark.
5. Other Chemical Reaction

Because batteries utilize a chemical reaction, battery per-

formance will deteriorate over time even if stored for a long 

period of time without being used. In addition, if the various 

usage conditions such as charge, discharge, ambient tempera-

ture, etc. are not maintained within the specified ranges, the 

  WiFly Bar RGBA                                  Battery Precautions

  WiFly Bar RGBA                                  Battery Precautions

Summary of Contents for WIFLY BAR RGBA

Page 1: ...h without the restrictions of power or DMX cabling The built in battery will keep charge for up to 10 hours full on from a full single charge This fixture can be used in a stand alone mode or connecte...

Page 2: ...ecommended by the manufacturer See page 29 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding ampl...

Page 3: ...LIR battery Should the electrolyte gel come into contact with the skin or eyes flush the area of contact immediately with fresh water and seek medical attention immediately 3 4 Do Not Expose the Batt...

Page 4: ...ure assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to sen...

Page 5: ...und lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior WiFly Bar RGBA Set Up DMX512 IN 3 PIN XLR SOU...

Page 6: ...el mode 18 Channel mode and a 34 Channel mode See pages 16 28 for each modes DMX traits WiFly Bar RGBA Operating Instructions displayed Then press the SET UP button to adjust intensity of the individu...

Page 7: ...tton until CH 04 is displayed This is the 4 Channel DMX Mode To run the 6 Channel Mode press the MODE button until CH 06 is displayed This is the 6 Channel DMX Mode To run the 7 Channel Mode press the...

Page 8: ...y address select your master unit and set your desired operating mode 3 Put the attenna to a upright position then turn the WiFly On using the WiFly power switch 4 For the Slave units put the unit in...

Page 9: ...t In Program mode Use the or to scroll through the built in 22 programs Once you have found your desired program and you can press the SPEED button and then use the and buttons to adjust the program s...

Page 10: ...hannel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 6 STROBING PROGRAM SPEED SOUND SENSITIVITY ADJUSTMENTS 0 15 NOTHING 16 25...

Page 11: ...2 PROGRAM 9 113 123 PROGRAM 10 124 134 PROGRAM 11 135 145 PROGRAM 12 146 156 PROGRAM 13 157 167 PROGRAM 14 168 178 PROGRAM 15 179 189 PROGRAM 16 190 200 PROGRAM 17 201 211 PROGRAM 18 212 222 PROGRAM 1...

Page 12: ...trol the speed of the programs When Channel 6 is between the values of 216 235 Programs 21 22 Channel 4 will let you select a flow color and Channel 5 will let you select a base color Channel 7 will c...

Page 13: ...8 Channel Mode Channel Value Function 1 RED 1 2 0 255 0 100 2 GREEN 1 2 0 255 0 100 3 BLUE 1 2 0 255 0 100 4 AMBER 1 2 0 255 0 100 5 RED 3 4 0 255 0 100 6 GREEN 3 4 0 255 0 100 7 BLUE 3 4 0 255 0 100...

Page 14: ...13 RED 4 0 255 0 100 14 GREEN 4 0 255 0 100 15 BLUE 4 0 255 0 100 16 AMBER 4 0 255 0 100 17 RED 5 0 255 0 100 WiFly Bar RGBA 34 Channel Mode Channel Value Function 18 GREEN 5 0 255 0 100 19 BLUE 5 0 2...

Page 15: ...11 115 254 165 98 0 Color44 231 235 8 107 222 0 Color21 116 120 254 121 0 0 Color45 236 240 107 156 231 0 Color22 121 125 176 17 0 0 Color46 241 245 165 198 247 0 Color23 126 130 96 0 11 0 Color47 246...

Page 16: ...y such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which ADJ Products LLC concludes af...

Page 17: ...WiFly Bar RGBA Notes ADJ Products LLC www adj com WiFly Bar RGBA User Manual Page 33 WiFly Bar RGBA Notes ADJ Products LLC www adj com WiFly Bar RGBA User Manual Page 34...

Page 18: ...rking position Power Draw 34W Power Cord Daisy Chain 20 Fixtures Max Fuse 2 Amp Weight 8lbs 3 5Kgs Dimensions 41 75 L x 3 W x 5 75 H 1060 x 73 x 145mm Colors RGBA Color Mixing DMX Channels 8 DMX Modes...