background image

P

ower Supply:

 The ADJ TRIBAR Spot contains a automatic voltage 

switch, which will auto sense the voltage when it is plugged into a 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The TRIBAR Spot can be controlled via DMX-512 protocol. The TRIBAR 

Spot has 7 DMX channel modes, please see page 9 for the different 

modes. The DMX address is set on the back panel of the TRIBAR Spot. 

Your unit and your DMX controller require a stan-

dard 3-pin XLR connector for data input and data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable (This cable may be purchased at almost all 

pro lighting stores). Your cables should be made 

with a male and female XLR connector on either 

end of the cable. Also remember that DMX cable 

must be daisy chained and cannot be split.

ADJ Products, LLC  -  www.adj.com  - TRIBAR Spot User Manual Page 5

  TRIBAR Spot                                                           Set Up

ADJ Products, LLC  -  www.adj.com  - TRIBAR Spot User Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

 TRIBAR Spot                                                             Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for MEGA TRI38 SYSTEM

Page 1: ...n spot system This lighting system features six RGB color mixing LED fixtures This fixture can be used in a stand alone mode or connected in a Master Slave configuration This system has six operating...

Page 2: ...point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sourc...

Page 3: ...ge 5 TRIBAR Spot Set Up ADJ Products LLC www adj com TRIBAR Spot User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the...

Page 4: ...g the SET UP button will display SP XX When this is dis played you can adjust the running speed of your desired program Use the UP or DOWN button to adjust the speed between SP 01 slowest and SP 99 fa...

Page 5: ...ntroller 2 To run your fixture in DMX mode press the MODE button until d XXX is displayed XXX represents the current displayed ad dress Use the UP or DOWN buttons to select your desired DMX address th...

Page 6: ...utton twice to enter the fade speed setting and use the buttons to adjust the fade speed FLASH This button will activate the strobe effect You can control the flash rate by pressing the and buttons Pr...

Page 7: ...the directions below to set your DMX Mode and address 1 Before connecting to an DMX controller your fixture has different DMX channel modes please select your desired mode by press ing the DMX Mode bu...

Page 8: ...BING 0 7 NO FUNCTION 8 255 STROBING SLOW FAST 6 MASTER DIMMER 0 255 0 100 TRIBAR Spot 6 Channel DMX Mode Note When Channel 4 is being used Channels 1 2 3 will not work Channel Value Function 1 RED 0 2...

Page 9: ...PROGRAM 21 226 235 PROGRAM 22 236 245 AUTO RUN 246 255 SOUND ACTIVE TRIBAR Spot 8 Channel DMX Mode Channel Value Function 6 PROGRAM SPEED SOUND SENSITIVITY 0 255 SLOW FAST 0 255 LEAST SENSITIVE MOST S...

Page 10: ...7 RED PINSPOTS 5 6 0 255 0 100 8 GREEN PINSPOTS 5 6 0 255 0 100 9 BLUE PINSPOTS 5 6 0 255 0 100 10 STROBING 0 7 NO FUNCTION 8 255 STROBING SLOW FAST 11 MASTER DIMMER 0 255 0 100 TRIBAR Spot 11 Channe...

Page 11: ...POT 1 0 255 0 100 2 GREEN PINSPOT 1 0 255 0 100 3 BLUE PINSPOT 1 0 255 0 100 4 RED PINSPOT 2 0 255 0 100 5 GREEN PINSPOT 2 0 255 0 100 6 BLUE PINSPOT 2 0 255 0 100 7 RED PINSPOT 3 0 255 0 100 8 GREEN...

Page 12: ...rom the unit Once the cord has been removed you will find that the fuse holder is located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse hold...

Page 13: ...labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including par...

Page 14: ...rking position Warranty 3 Year 1 095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Vol...