  Channel   Value  

                  Function

       

1                                                        RED

                       0 - 255                          0% - 100%           

       2                                                      GREEN

                       0 - 255                          0% - 100%

       3                                                       BLUE

                       0 - 255                          0% - 100%

       4                                             COLOR MACROS

                       0 - 255   (

Please see the color macro chart page 23)

           

       5                                                  PROGRAMS

                       0 - 15                        NO FUNCTION

                     16 - 25                          PROGRAM 1

                     26 - 35                          PROGRAM 2

                     36 - 45                          PROGRAM 3

                     46 - 55                          PROGRAM 4

                     56 - 65                          PROGRAM 5

                     66 - 75                          PROGRAM 6

                     76 - 85                          PROGRAM 7

                     86 - 95                          PROGRAM 8

                     96 - 105                        PROGRAM 9

                   106 - 115                       PROGRAM 10

                   116 - 125                       PROGRAM 11

                   126 - 135                       PROGRAM 12

                   136 - 145                       PROGRAM 13

                   146 - 155                       PROGRAM 14

                   156 - 165                       PROGRAM 15

                   166 - 175                       PROGRAM 16

                   176 - 185                       PROGRAM 17

                   186 - 195                       PROGRAM 18

                   196 - 205                       PROGRAM 19

                   206 - 215                       PROGRAM 20

                   216 - 225                       PROGRAM 21

                   226 - 235                       PROGRAM 22

                   236 - 245                          AUTO RUN

                   246 - 255                      SOUND ACTIVE

  TRIBAR Spot                                     8 Channel DMX Mode

  Channel   Value  

                  Function

       

6                           PROGRAM SPEED/SOUND SENSITIVITY

                       0 - 255                       SLOW - FAST

                       0 - 255   LEAST SENSITIVE - MOST SENSITIVE

       7                                                   STROBING

                       0 - 7                           NO FUNCTION

                       8 - 255              STROBING SLOW - FAST

       8                                             MASTER DIMMER

                       0 - 255                          0% - 100%

  TRIBAR Spot                                     8 Channel DMX Mode

Note: When Channel 4 is being used, Channels 1, 2, & 3 will not work.
When Channel 5 is between the values of 16 - 235 , Channel 6 will 

control the speed of the programs.
When Channel 5 is between the values of 216 - 235 (Programs 21 & 

22), Channel 3 will let you select a flow color, and Channel 4 will let 

you select a base color. Channel 6 will control the speed of the flow 

color. See the Color Macro Chart on page 22 to select your flow color 

and base color.
When Channel 5 is between the values of 246 - 255 , Channel 6 will 

control the sound sensitivity.

Summary of Contents for MEGA TRI38 SYSTEM

Page 1: ...n spot system This lighting system features six RGB color mixing LED fixtures This fixture can be used in a stand alone mode or connected in a Master Slave configuration This system has six operating...

Page 2: ...point they exit from the unit Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 24 for cleaning details Heat The appliance should be situated away from heat sourc...

Page 3: ...ge 5 TRIBAR Spot Set Up ADJ Products LLC www adj com TRIBAR Spot User Manual Page 6 Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the...

Page 4: ...g the SET UP button will display SP XX When this is dis played you can adjust the running speed of your desired program Use the UP or DOWN button to adjust the speed between SP 01 slowest and SP 99 fa...

Page 5: ...ntroller 2 To run your fixture in DMX mode press the MODE button until d XXX is displayed XXX represents the current displayed ad dress Use the UP or DOWN buttons to select your desired DMX address th...

Page 6: ...utton twice to enter the fade speed setting and use the buttons to adjust the fade speed FLASH This button will activate the strobe effect You can control the flash rate by pressing the and buttons Pr...

Page 7: ...the directions below to set your DMX Mode and address 1 Before connecting to an DMX controller your fixture has different DMX channel modes please select your desired mode by press ing the DMX Mode bu...

Page 8: ...BING 0 7 NO FUNCTION 8 255 STROBING SLOW FAST 6 MASTER DIMMER 0 255 0 100 TRIBAR Spot 6 Channel DMX Mode Note When Channel 4 is being used Channels 1 2 3 will not work Channel Value Function 1 RED 0 2...

Page 9: ...PROGRAM 21 226 235 PROGRAM 22 236 245 AUTO RUN 246 255 SOUND ACTIVE TRIBAR Spot 8 Channel DMX Mode Channel Value Function 6 PROGRAM SPEED SOUND SENSITIVITY 0 255 SLOW FAST 0 255 LEAST SENSITIVE MOST S...

Page 10: ...7 RED PINSPOTS 5 6 0 255 0 100 8 GREEN PINSPOTS 5 6 0 255 0 100 9 BLUE PINSPOTS 5 6 0 255 0 100 10 STROBING 0 7 NO FUNCTION 8 255 STROBING SLOW FAST 11 MASTER DIMMER 0 255 0 100 TRIBAR Spot 11 Channe...

Page 11: ...POT 1 0 255 0 100 2 GREEN PINSPOT 1 0 255 0 100 3 BLUE PINSPOT 1 0 255 0 100 4 RED PINSPOT 2 0 255 0 100 5 GREEN PINSPOT 2 0 255 0 100 6 BLUE PINSPOT 2 0 255 0 100 7 RED PINSPOT 3 0 255 0 100 8 GREEN...

Page 12: ...rom the unit Once the cord has been removed you will find that the fuse holder is located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse hold...

Page 13: ...labor by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including par...

Page 14: ...rking position Warranty 3 Year 1 095 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Vol...

Reviews: