American DJ
®
- www.americandj.com - GP 250™ Instruction Manual Page 17
American DJ
®
- www.americandj.com - GP 250™ Instruction Manual Page 18
GP 250™
Gobo Replacement
This unit comes with interchangable gobos. Changing the
gobos is a easy procedure. Follow the instructions below.
Caution!
Never open the unit when in use. Always disconnect
the main power before attempting to change the gobos.
1. To change the gobo, you must remove the top half of the
unit.
2. First unscrew the four phillips screws on the top half of the
shell. Remove the top half of the shell.
3. When you remove the top shell you will be able to access the
colored gobo wheel. Turn the wheel with your hand until you
come across the gobo you would like to change.
4. Remove the fixation-ring with a small flat-head screwdriver.
Push the gobo out towards the rear. When doing this you
do not need a lot of pressure.
5. Change the gobo, replace the fixation-ring, and reassemble
the unit.
GP 250™
Cleaning
GP 250™
Trouble Shooting
Trouble Shooting:
Listed below are a few common problems
that you may encounter, with solutions.
No light output from the unit;
1. Be sure you have connected your unit into a standard 120v
wall outlet.
2. Be sure the external fuse has not blown. The fuse is located
on the back panel of the unit inside the power socket.
3. Remove the lamp holder and be sure the lamp is seated in
its socket properly. Occasionally lamps become loose dur-
ing shipping be sure the lamp is push in to its socket all the
way.
4. Be sure the fuse holder is completely and properly seated.
Unit does not respond to sound;
1. Low frequencies (bass) should cause the unit to react to
sound. Tapping on the microphone, quiet or high pitched
sounds may not activate the unit.
Fixture Cleaning:
Due to fog residue, smoke, and dust clean-
ing the internal and external optical lenses and mirror should be
carried out periodically to optimize light output. Cleaning fre-
quency depends on the environment in which the fixture oper-
ates (I.e. smoke, fog residue, dust, dew). In heavy club use we
recommend cleaning on a monthly basis. Periodic cleaning will
ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics and mirror with glass cleaner and a
soft cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth
every 30-60 days.
5. Always be sure to dry all parts completely before plugging
the unit back in.