background image

American DJ

®

  -  www.americandj.com  - GP 250™ Instruction Manual Page 14

American DJ

®

  -  www.americandj.com  - GP 250™ Instruction Manual Page 13

 GP 250™ 

                                         Fuse & Lamp Replacement

Caution:

 

Always  replace  with  the  exact  same  type  lamp  and  fuse, 

unless  otherwise  specified  by  an  authorized  American  DJ

®

  service 

technician. Replacing with anything other than the specified part can 
damage your unit and will void your manufactures warranty.

Warning: 

If  you  continue  to  blow  lamps  or  fuses,  STOP  using  the 

unit. Contact customer support for further instructions, you may have 
to return the unit for servicing. Continuing to use the unit may cause 
serious damage.

Lamp  Replacement:

 

Caution!  Never  attempt  to  change  the  lamp 

while  the  fixture  is  plugged  in.  Always  disconnect  the  main  power 
and  allow  the  unit  ample  time  to  cool  before  attempting  to  replace 
the lamp. Lamp replacement has been made simple by incorporating 
a slide out lamp assembly that is retained by two phillips screws.
1.   Be sure to follow the proper handling procedures that deal with  
 

discharge lamps.

2.   Unscrew the two thumb screws (A,B) on the rear of the unit 
3.   After removing the screws, gently slide out the socket assembly  
      from the rear of the unit to expose the lamp.
4.  Carefully remove the old lamp and discard it in the trash.
5.  Replace the lamp with an exact match and reassemble in reverse  
 

order.

6.  After replacing the lamp follow the optimization procedures on the  
 

next page to be sure the lamp is center in the reflector

A

B

Optimizing  Lamp  Alignment: 

This  procedure  centers  the  lamp  in 

the reflector. Proper optimization will increase lamp life and ensure a 
bright crisp output. Improper optimization may add a yellow tint to the 
lamp output and reduce intensity.
1.  Be sure main power is disconnected and allow the unit to cool. If  
 

the you have just installed a new unit you can obviously skip this 

 

step.

2.   Make a preliminary adjustment: Turn the three lamp adjustment
 

thumb screws completely in (clockwise). Then back them each  

 

out (counter-clockwise) about three complete turns.

3.   Turn the unit on and allow it to reset.
4.   Using either a DMX controller or the control panel on the unit, 
 

strike the lamp and focus the light on a flat surface. 

5.   Center the hot-spot (the brightest part of the beam) using the 3 
 

adjustment screws. Turn one screw at a time to drag the hot-spot 

 

diagonally across the projected image. If you cannot detect a hot-

 

spot, adjust the lamp until the light is even.

6.   To reduce a hot-spot, pull the lamp in by turning all three screws 
 

clockwise 1/4-turn at a time until the light is evenly distributed.

7.   If the light is brighter around the edge than it is in the center, or if 
 

light output is low, the lamp is too far back in the reflector. “Push” 

 

the lamp out by turning the screws.

 GP 250™ 

                                         Fuse & Lamp Replacement

Optimizing Screws

Optimizing Screws

Fuse Replacement:

 Locate and remove the unit’s power cord. Once 

the cord has been removed located the fuse holder located inside the 
power  socket.  Insert  a  flat-head  screw  driver  into  the  power  socket 
and gently pry out the fuse holder. Remove the bad fuse and replace 
with a new one. The fuse holder has a built-in socket for a spare fuse 
be sure not to confuse the spare fuse with active fuse.

Summary of Contents for GP 250

Page 1: ...gobos The fixture can operate in three different operating modes stand alone sound active or in a Master Slave configuration The GP 250 comes with several built in programs and is best used in multiples of four When used as a stand alone unit or when used in multiples linked in a master slave configuration For best results use fog or special effects smoke to enhance the beams projections Customer ...

Page 2: ...ng amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance GP 250 Safety Precautions GP 250 Halogen Lamp Warning Caution There are no user servicea...

Page 3: ... and Functions 1 Power Cord Inlet and Fuse Holder Power Cord Inlet This unit is equipped with a removable I E C power cord Be sure to only use the power cord included with the unit this cord is designed to match the electrical requirements of the unit Other cords may cause the unit to overheat or malfunction Voltage may vary from venue to venue when connecting this unit to a power supply be sure t...

Page 4: ...embly This high quality lens is a fully focusing Focus the lens by manually turning the lens in a clockwise or counter clockwise direction until the desired effect is achieved Power Supply Before plugging your unit in be sure the source voltage in your area matches the required voltage for your American DJ GP 250 The American DJ GP 250 is available in a 120v and 220v version Because line voltage m...

Page 5: ...512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 2 GP 250 Set Up Figure 3 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 H...

Page 6: ...et use a terminator on the last fixture 6 For more help operating in DMX mode consult the manual includ ed with your DMX controller Stand Alone Operation Sound Active This mode allows a single unit or several units linked together to run to the beat of the GP 250 Operation GP 250 Operation music 1 To operate the unit in Sound Active mode Set dipswitch 10 and 11 to the on position See dipswitch set...

Page 7: ...nt This procedure centers the lamp in the reflector Proper optimization will increase lamp life and ensure a bright crisp output Improper optimization may add a yellow tint to the lamp output and reduce intensity 1 Be sure main power is disconnected and allow the unit to cool If the you have just installed a new unit you can obviously skip this step 2 Make a preliminary adjustment Turn the three l...

Page 8: ... x x x x x x 0 1 0 Slave x x x x x x x x x x 1 1 0 AloneSound 0 0 0 0 0 0 0 0 0 0 1 0 0 Sound Active 1 1 0 0 0 0 0 0 0 0 1 0 0 Gobo1 2 0 1 0 0 0 0 0 0 0 1 0 0 Gobo2 3 1 1 0 0 0 0 0 0 0 1 0 0 Gobo3 4 0 0 1 0 0 0 0 0 0 1 0 0 Gobo4 5 1 0 1 0 0 0 0 0 0 1 0 0 Gobo5 6 0 1 1 0 0 0 0 0 0 1 0 0 Gobo 1 shake 7 1 1 1 0 0 0 0 0 0 1 0 0 Gobo 2 shake 8 0 0 0 1 0 0 0 0 0 1 0 0 Gobo 3 shake 9 1 0 0 1 0 0 0 0 0 1 ...

Page 9: ...andard 120v wall outlet 2 Be sure the external fuse has not blown The fuse is located on the back panel of the unit inside the power socket 3 Remove the lamp holder and be sure the lamp is seated in its socket properly Occasionally lamps become loose dur ing shipping be sure the lamp is push in to its socket all the way 4 Be sure the fuse holder is completely and properly seated Unit does not resp...

Page 10: ...ch American DJ concludes after inspection affects the reli ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorization was issued to purchaser by American DJ if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does n...