background image

American DJ

®

  -  www.americandj.com  - GP 250™ Instruction Manual Page 8

American DJ

®

  -  www.americandj.com  - GP 250™ Instruction Manual Page 7

 GP 250™    

                          Controls and Functions

 GP 250™   

             

                                 Set Up

3.  XLR DMX Input Jack -

 This jack is used to receive an incoming 

DMX  signal or Master/Slave signal.

4.  Dipswitches -

 These switches serve two functions. In master-slave 

mode these switches are used to assign a specific head address. In 
DMX mode these switches are used to assign a DMX address to the 
unit. In DMX mode each switch corresponds to a specific value based 
on  binary  code.  See  pages  8-10  for  a  detailed  explanation  of  DMX 
binary code.

5. Audio Sensitivity Knob - 

This will adjust the audio sensitivity of the 

INTERNAL MICROPHONE. Turning the sensitivity knob in the clock-
wise direction will increase the sensitivity to sound. Turning the knob 
in the counter clockwise direction will decrease the fixture’s sensitivity 
to sound.

6.  MINI/C  Controller  Jack  - 

This  jack  is  for  use  with  the  optional 

MINI/C controller only. This controller is used to control the blackout 
function. Do not attempt to connect an audio signal to this jack, this 
will damage the PC board and void your manufactures warranty!

7.  Lamp  Assembly  and  Access  Plate  -

  This  plate  accesses  the 

lamp socket assembly. The unit includes a spring mounted ZB-EHJ5 
250w  halogen  lamp.  Be  sure  to  only  replace  with  same  type  lamp. 
After replacing a lamp be sure the lamp is centered in the reflector. 
See pages 13-14 for details on installing and optimizing replacement 
lamps. Never operate this unit with the lamp exposed, this lamp emits 
strong UV radiation.

8.  Cooling Fan - 

This unit is equipped with two high velocity variable 

fans to aid in the cooling process. These fans are designed to vary their 
velocity at different operating temperatures, to provide better cooling 
when the unit reached higher operating temperatures associated with 
long usage. Be sure to never obstruct the cooling fans during normal 
usage. Also, be sure to keep the vents clean at all times. A blocked or 
malfunctioning cooling system may shorten lamp life and unit reliabil-
ity.

9.  Lens Assembly -

 This high quality lens is a fully focusing. Focus the 

lens by manually turning the lens in a clockwise or counter-clockwise 
direction until the desired effect is achieved.

Power  Supply:

  Before  plugging  your  unit  in,  be  sure  the  source 

voltage in your area matches the required voltage for your American 
DJ

®

 GP 250.™ The American DJ

®

 GP 250

 is available in a 120v and 

220v  version.  Because  line  voltage  may  vary  from  venue  to  venue, 
you should be sure your unit voltages matches the wall outlet voltage 
before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dip-switches in DMX mode:

 This unit uses dip switches to assign a 

DMX address. Each dip switch represents a binary value. 
Dip Switch 1 address equals 1 

 

Dip Switch 2 address equals 2 

 

Dip Switch 3 address equals 4 

 

Dip Switch 4 address equals 8 
Dip Switch 5 address equals 16 

 

Dip Switch 6 address equals 32
Dip Switch 7 address equals 64 

 

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

Dipswitches 10, 11, and 12 - Some units omit dipswitch 10, and most 
units do not have dipswitches 11 and 12. When a unit does include 

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

Summary of Contents for GP 250

Page 1: ...gobos The fixture can operate in three different operating modes stand alone sound active or in a Master Slave configuration The GP 250 comes with several built in programs and is best used in multiples of four When used as a stand alone unit or when used in multiples linked in a master slave configuration For best results use fog or special effects smoke to enhance the beams projections Customer ...

Page 2: ...ng amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance GP 250 Safety Precautions GP 250 Halogen Lamp Warning Caution There are no user servicea...

Page 3: ... and Functions 1 Power Cord Inlet and Fuse Holder Power Cord Inlet This unit is equipped with a removable I E C power cord Be sure to only use the power cord included with the unit this cord is designed to match the electrical requirements of the unit Other cords may cause the unit to overheat or malfunction Voltage may vary from venue to venue when connecting this unit to a power supply be sure t...

Page 4: ...embly This high quality lens is a fully focusing Focus the lens by manually turning the lens in a clockwise or counter clockwise direction until the desired effect is achieved Power Supply Before plugging your unit in be sure the source voltage in your area matches the required voltage for your American DJ GP 250 The American DJ GP 250 is available in a 120v and 220v version Because line voltage m...

Page 5: ...512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 2 GP 250 Set Up Figure 3 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 H...

Page 6: ...et use a terminator on the last fixture 6 For more help operating in DMX mode consult the manual includ ed with your DMX controller Stand Alone Operation Sound Active This mode allows a single unit or several units linked together to run to the beat of the GP 250 Operation GP 250 Operation music 1 To operate the unit in Sound Active mode Set dipswitch 10 and 11 to the on position See dipswitch set...

Page 7: ...nt This procedure centers the lamp in the reflector Proper optimization will increase lamp life and ensure a bright crisp output Improper optimization may add a yellow tint to the lamp output and reduce intensity 1 Be sure main power is disconnected and allow the unit to cool If the you have just installed a new unit you can obviously skip this step 2 Make a preliminary adjustment Turn the three l...

Page 8: ... x x x x x x 0 1 0 Slave x x x x x x x x x x 1 1 0 AloneSound 0 0 0 0 0 0 0 0 0 0 1 0 0 Sound Active 1 1 0 0 0 0 0 0 0 0 1 0 0 Gobo1 2 0 1 0 0 0 0 0 0 0 1 0 0 Gobo2 3 1 1 0 0 0 0 0 0 0 1 0 0 Gobo3 4 0 0 1 0 0 0 0 0 0 1 0 0 Gobo4 5 1 0 1 0 0 0 0 0 0 1 0 0 Gobo5 6 0 1 1 0 0 0 0 0 0 1 0 0 Gobo 1 shake 7 1 1 1 0 0 0 0 0 0 1 0 0 Gobo 2 shake 8 0 0 0 1 0 0 0 0 0 1 0 0 Gobo 3 shake 9 1 0 0 1 0 0 0 0 0 1 ...

Page 9: ...andard 120v wall outlet 2 Be sure the external fuse has not blown The fuse is located on the back panel of the unit inside the power socket 3 Remove the lamp holder and be sure the lamp is seated in its socket properly Occasionally lamps become loose dur ing shipping be sure the lamp is push in to its socket all the way 4 Be sure the fuse holder is completely and properly seated Unit does not resp...

Page 10: ...ch American DJ concludes after inspection affects the reli ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorization was issued to purchaser by American DJ if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does n...

Reviews: