background image

©

American DJ

®

  -  www.americandj.com - Galaxian Gem LED Instruction Manual Page 9

©

American DJ

®

  -  www.americandj.com - Galaxian Gem LED Instruction Manual Page 10

  Galaxian Gem LED  

 

 

                       Set Up

  Galaxian Gem LED  

 

 

                       Set Up

a male and female XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained and cannot be split.

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Summary of Contents for Galaxian Gem LED

Page 1: ...r DMX con trolled The Galaxian Gem LED can operate as a stand alone fixture or in a Master Slave configuration For best results use fog or special effects smoke to enhance the beams projections Custom...

Page 2: ...is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Powe...

Page 3: ...eye exposure In the laser safety regulation it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor...

Page 4: ...xture controlled by the controller could be the last fixture in the chain When a fixture is as signed a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no mat...

Page 5: ...ta Compliment negative Pin 1 Ground Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 110 1...

Page 6: ...1 Press the MENU button until SLND is displayed press ENTER MSTR SL 1 or SL 2 will be displayed 2 Press the UP or DOWN buttons until your desired setting is dis played press ENTER to confim and exit...

Page 7: ...ivate Blackout mode select No and press Enter LED With this function you can have the LED display turn off after 10 seconds 1 Press the MENU button until LED is displayed press ENTER 2 The display wil...

Page 8: ...controls Sound Active Mode This mode allows either single unit or several units linked together to run to the beat of the music Galaxian Gem LED Operation 1 Tap the MENU button until SOUN is displaye...

Page 9: ...er and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates I e smoke fo...

Page 10: ...any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products describe...

Reviews: