background image

 12 

 5. Troubleshooting  

 

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

C. Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling. Check the LED for the response of the 

master/ slave mode signal. 

2.  Wrong DMX address in the unit. Set the proper address. 

D. No response to the sound 

1.  Make sure the unit does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone 

 

 

 

 

 

 

 

 

 13

  6. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

accumulation of dirt on the unit’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Fusion FX Bar 2

Page 1: ...X Bar 2 User Guide Professional Entertainment Technology 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixture...

Page 2: ...hnical assistance center Always use the same type spare parts y Do not touch any wire during operation as high voltage might be causing electric shock Warning y To prevent or reduce the risk of electr...

Page 3: ...e function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup or it will automatically return...

Page 4: ...de Once the mode has been selected press the ENTER button to store or it will automatically return to the main functions without any change after idling 8 seconds To go back to the main functions with...

Page 5: ...ilt in programs 9 4 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated sync...

Page 6: ...able can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the syst...

Page 7: ...oltage cables that may cause damage or interference to DMX interface circuit C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response...

Page 8: ...rovision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Har...

Reviews: