background image

12

Troubleshooting

Never try to repair or dismantle the air condition yourself. 
Incompetent repairs result in loss of warranty and can endanger the user and the property.

The air 
conditioner does 
not function.

*

No power supply.  Make sure the 
green light on the plug is lit.

Connect to a functioning outlet and switch on.
See below for Plug and Reset button application.

Is the power light  ashing?
Is the water full LED lit?

Empty the water container.

The air 
conditioner does 
not seem to 
perform.

The unit is in direct sunlight. 

Close curtains/shades

Windows or doors open, many
people or a heat source in the room.

Close doors and windows.  Unit is not made to 
cool server rooms, sun rooms, or any rooms 
generating a constant 

The filter is dirty.

Clean the  filter.

Air inlet or air outlet blocked.

Power off the unit and unplug from outlet.  
Remove blockage.

Room temperature lower than the 
selected value.

Change temperature selection. 
Set at the lowest possible setting: 60°F.

The unit is noisy. Unit stands uneven.

Place on an even, solid surface (less vibrations).

The compressor 
does not work.

The overheat protection may be 
activated.

Wait 30 minutes until the temperature has 
decreased, then turn on the unit again.

The remote 
control does not 
function.

Distance too great.

Make sure the remote control is correctly aimed 
at the control panel.

Remote control signal not detected 
by the control panel.

The batteries are drained.

Check batteries on remote.

Note: When abnormal situations occur, turn off machine and pull out plug, then contact 
with professional electrician for help

* LCDI Plug 

If you plug in the Air Conditioner, and there is no green light on the plug, 
press the reset button on the LCDI plug.  The green light should be lit, 
indicating that the air conditioner is getting power from the electrical outlet.

 
  Make sure unit is plugged directly into a dedicated electrical source/outlet.  

Do not use any extension cords. See electrical specif cations listed on 
page 3 and make sure the electrical source can accommodate the unit’s 
energy consumption.

 
  If the plug continues to trip (which is a USA national safety standard feature) 

and the green light goes off, the cord may be damaged preventing you from 
resetting the unit. For your safety, contact a licensed electrician.

TEST 

RESET

Reset Button

Green Light

Test Button

Problem

Cause

Solution

Summary of Contents for ACW613C

Page 1: ...MODEL ACW613C...

Page 2: ...nts ThankYou 1 Safety Instructions 1 2 Specifications 3 Parts 4 Positioning 5 Control Panel 6 Remote Control 7 Multi Protective Function 8 Emptying the Water Container 9 Cleaning 10 Troubleshooting 11...

Page 3: ...rate this appliance if it has a damaged cord or plug Do not lead the cord over sharp edges A damaged supply cord should be replaced by the manufacturer its service agent or a quali ed person in order...

Page 4: ...aste This product should be taken to your local recycling center for safe treatment Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the powe...

Page 5: ...1 300W 11 5A 58 pints day 64 86 44 95...

Page 6: ...ual to learn how to use them Top Cover Handle Upper Filter frame Exhaust Connector Power Cord Location Lower Filter Frame Rubber Plug Plug Cap Power Supply Cord Control Panel Air Outlet Exhaust Hose S...

Page 7: ...ssemble the hot air hose on the unit Clip on the water atomizer at the end of the spiral pipe to the holder Unfold exible hose with attached hose adapter connector and snap into Window Slide Bar AutoD...

Page 8: ...r window and stays in place Proceed to close and lock your window on the Slide Bar to secure in place Figure C IMPORTANT The exible hose can be extended from 10 63 to 59 for mounting We recommend that...

Page 9: ...set your time with UP and DOWN buttons You can set auto shut off time when the unit is running you can also set auto running time when the unit is off When you finishing the setting icon will continu...

Page 10: ...key to choose Celcius or Fahrenheit 8 SLEEPING Only under cooling or heating function Press this key to enable this function 9 TIMER Press this key to set time Within 5 hours time interval is half hou...

Page 11: ...l open when the protection function runs a When checking the water level protection compressor must work After 10 seconds moving the water level switch will go to stability that is water level protect...

Page 12: ...the water s i h t t a e p e R t i y t p m e d n a w o l f process until all water has been removed For seasonal storage purposes put the unit ON in fan mode on a warm dry day for a couple of hours to...

Page 13: ...h g i l r e t l i f ove loose dust and dirt from the g n i n n u r r e d n u y l h g u o r o h t m e h t e s n i r n e h t d n a s r e t l i f water You may also immerse it gently into warm water wit...

Page 14: ...does not work The overheat protection may be activated Wait 30 minutes until the temperature has decreased then turn on the unit again The remote control does not function Distance too great Make sure...

Page 15: ...S NOT COVER Damage accidental or otherwise to the unit while in the possession of the consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure t...